README Template 71.1 (please do not delete the README Template Version line!) ESO Programme ID: 071.B-0091(A) Principal Investigator Name: Victor P. Debattista Principal Investigator E-mail Address: debattis@phys.ethz.ch Principal Investigator Telephone Number: +41-01-633-2824 Principal Investigator Postal Address: Institut fuer Astronomie / ETH Hoenggerberg / HPF G4.2 / CH-8093 / Zuerich / Switzerland Instrument: ISAAC OPC Priority Class: B OPC Approved Total Execution Time: 8.0 Estimated Total Execution Time (including overheads): 8.0 README File Submission Date: 04 March 2003 Programme Description ===================== General Overview ---------------- This is a long-slit spectroscopy programme aimed to measure the bar pattern speed of the SBc galaxy NGC 4123. We plan to take: 1) 1x35min SWS1-MR spectra along the galaxy major axis (PA = 147 degrees) with the galaxy nucleus centered in the slit; 2) 2X30min SWS1-MR spectra with the slit parallel to the galaxy major axis (PA = 147 degrees) with the slit center offset by 15 arcsec EASTWARD the nucleus; 3) 2X30min SWS1-MR spectra with the slit parallel to the galaxy major axis (PA = 147 degrees) with the slit center offset by 15 arcsec WESTWARD the nucleus; 4) 2X40min SWS1-MR spectra with the slit parallel to the galaxy major axis (PA = 147 degrees) with the slit center offset by 30 arcsec EASTWARD the nucleus; 5) 2X40min SWS1-MR spectra with the slit parallel to the galaxy major axis (PA = 147 degrees) with the slit center offset by 30 arcsec WESTWARD the nucleus; The position angle of the galaxy major axis (PA=147deg) has been measured from the surface photometry of the outer regions of the galaxy disk. The off-nucleus spectra with the slit parallal to the galaxy major axis have to be obtained by pointing to the galaxy nucleus and then applying a blind offset as specified in the relevant OB's. The offset for nodding through the slit are specified. The acquisition Ks-band images will be used in data analysis. Therefore please DO NOT SKIP Ks-band acquisition images when taking the second spectrum in the same position. The 2MASS Survey does not list any object of the target field (12arcmin x 12arcmin). We assume that all the field stars have K>12 mag. The central surface brightness of NGC4123 is K=16 mag/arcsec^2. Approved Waiver Request Summary ------------------------------- None. Critical Observing Condition Constraints ---------------------------------------- The ZERO_NGC4321_MajAx OB has to be executed under photometric conditions. Time Critical Aspects --------------------- None. Special Calibration Information ------------------------------- Standard calibration are needed for spectroscopy (darks, flats, star traces, telluric standard stars, arcs) and acquisition Ks-band images (darks, twilight flst fields, zeropoints, illumination corrections). We asked fot nighttime arc exposures to ensure for an accurate wavelength calibration. This is necessary for measuring stellar kinematics. ToO Information --------------- This is not a ToO programme. Pre-Imaging Requirements ------------------------ No pre-imaging is required for this programme. OB Information ============== List of Science OBs with Associated Finding Charts -------------------------------------------------- Total Number of Submitted Science OBs: 9 Total Number of Submitted Finding Charts: 5 ZERO_NGC4123_MajAx = 71.B-0091A.001.ps NGC4123_OffAx15E_1 = 71.B-0091A.002.ps NGC4123_OffAx15E_2 = 71.B-0091A.002.ps NGC4123_OffAx15W_1 = 71.B-0091A.003.ps NGC4123_OffAx15W_2 = 71.B-0091A.003.ps NGC4123_OffAx30E_1 = 71.B-0091A.004.ps NGC4123_OffAx30E_2 = 71.B-0091A.004.ps NGC4123_OffAx30W_1 = 71.B-0091A.005.ps NGC4123_OffAx30W_2 = 71.B-0091A.005.ps List of Calibration OBs with Associated Science OBs --------------------------------------------------- None OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y] [FORS only] Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [NA] [FORS only] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [NA] [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page ? [Y] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [WFI only]Are your finding charts 34 arcmin x 34 arcmin? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.