README Template 71.1 (please do not delete the README Template Version line!) ESO Programme ID: 71.A-3071B Principal Investigator Name: Prof. Simon Lilly Principal Investigator E-mail Address: lilly@phys.ethz.ch Principal Investigator Telephone Number: (+41) 1-633-3828 Principal Investigator Postal Address: Institute for Astronomy ETH Hoenggerberg, HPF G4 CH-8093 Zurich, Switzerland Instrument: VIMOS OPC Priority Class: A OPC Approved Total Execution Time: 20:00:00 Estimated Total Execution Time (including overheads): 20:00:00 README File Submission Date: 14/07/2003 Programme Description ===================== General Overview ---------------- ** 14/07/03 ** Version 4 Same mask design as Version 3. Observing strategy modified slightly to take 6 dithers along slit so the total exposure for each y-postion is 2850 sec. ** 08/07/03 ** Version 3 Like Version 2 except now the left-most slits in Quad 1 & 4 are shorter (85 pix); right-most slits in Quad 2 & 3 remain shorter. Also have increased distance b/w the 10 subslits; "bridges" are now 4" wide instead of 2". No changes in observing strategy. ** 05/07/03 ** Version 2 Only 1 OB of 12 submitted in this version. Purpose is to test if masks can be cut so they can be inserted into VIMOS. ADP's have been modified so that most southern (right-most) slits in each quadrant are only half the length (98pix instead of 195pix) of the others. Otherwise no changes to observing strategy. ** Edited from 28/06/03 version ** Multiple long-slit blind spectroscopic survey targeted at (RA, Dec) = (22:17:38, +00:18:30). Intermediate (MR) grism used in combination with V filter to limit wavelength coverage to ~5100-6000A. The VIMOS mask is composed of 7 long parallel slits spaced 77" apart on each quadrant. Long slits are oriented N/S where each long slit is composed of ten shorter 40" slits placed end to end and separated by 2". There is one reference star in each quadrant to ensure correct alignment of the mask and exact location of the pointing. The VIMOS mask we have designed with VMMPS uses pre-imaging taken of the 22hr field where the center is (22:17:42, +00:17:30). However, once the field is acquired such that the reference stars are in their boxes, offsets as large as -87" in y (RA) and -70" in x (Dec) are required. Using guidecamLite, we have located a GUIDESTAR observable for all our OB's that does not vignet the field. PLEASE USE THE FOLLOWING GUIDESTAR FOR ALL OF OUR OBSERVATIONS: 22:18:20.215 +00:24:33.66 mag=13.0 (in "alternate" position") Because this is a blind survey, it is imperative that we know the exact location of each pointing. Thus using the same guidestar should ensure that each x/y offset be done with minimal error (<0.1"). The observing strategy is to step the mask 1.5" in y (East/West) 20 times to map part of the VIMOS field of view. At each y-position, 6 exposures are taken where each exposure is stepped by 5" in x (parallel to slit) to facilitate flat-fielding and removal of the "bridges" between the short 40" slits. The total integration at each y-position is 2850sec and is composed of 6x475sec exposures. Each OB contains two y-pointings. Approved Waiver Request Summary ------------------------------- APPROVED: - Intermediate (MR) grism + V filter combo - OB's that take up to 2 hrs - flux calibrations taken w/ MR grim+V filter (not charged against our total time) Critical Observing Condition Constraints ---------------------------------------- NONE Time Critical Aspects --------------------- If possible, please send results from the first executed OB before taking the others. We will know from the first observations if any spatial adjustements for the other OB's are needed. Raw data is perfectly acceptable for this quick check. Special Calibration Information ------------------------------- Flux calibrations using the MR grism + V filter combo required. We have been told the time to obtain these calibrations will not be charged against our allocation. ToO Information --------------- NA Pre-Imaging Requirements ------------------------ NA OB Information ============== List of Science OBs with Associated Finding Charts -------------------------------------------------- Total Number of Submitted Science OBs: 10 Total Number of Submitted Finding Charts: 1 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y/N/NA] NA (waiver requests have been granted) If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y/N/NA] NA Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y/N/NA] NO [FORS only] Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [Y/N/NA] [FORS only] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [Y/N/NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page ? [Y/N/NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided ISAAC*_*_cal_* templates? [Y/N/NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] [WFI only]Are your finding charts 34 arcmin x 34 arcmin? [Y/N/NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.