README Template 71.1 ESO Programme ID: 71.A-0407(B) Principal Investigator Name: Sluse Dominique Principal Investigator E-mail Address: sluse@astro.ulg.ac.be Principal Investigator Telephone Number: 00 32 4 3669761 Principal Investigator Postal Address: Institut d'astrophysisque et de Geophysique, Fac.Sc., Universite de Liege, Allee du 6 aout 17, B5C, B4000 Sart Tilman, Belgique Instrument: FORS2 OPC Priority Class: A OPC Approved Total Execution Time: 2h Estimated Total Execution Time (including overheads): 1h59m42s README File Submission Date: 060303 Programme Description ===================== General Overview ---------------- This is a spectroscopic program of the different components of a gravitational lens system with two slit orientations and two grisms. Bin 1x1 is requested (accepted in Phase 1; see original proposal+waiver) in order to separate at best the different components of this gravitationaly lensed system. Seeing 0.6'' or better is mandatory. The two slit orientations are respectively (see Finding chart) along components B-C and A-D components. PA have been provided in the acquisition template in order to have the field correctly oriented. Approved Waiver Request Summary ------------------------------- We propose to observe a new gravitationnaly lensed system with components separated by less then 1.2 arcsec with seeing 0.6 arcsec. Since it is imperative to spatially separate each component of the system, we wanted to use the HR-collimator. After discussion with Thomas Szeifert (FORS instrument scientist in Paranal), we learned that this mode has a very bad efficiency and that the binning 1x1 with SR-collimator is much preferable to have a good efficiency and the pixel size small enough to spatially separate the spectra under the requested seeing (0.6 arcsec). WaiverID: 71.A-0407B.01 Accepted by Mario van den Ancker, ESO - User Support Group the 050303 Critical Observing Condition Constraints ---------------------------------------- Seeing 0.6'' or better is mandatory. Time Critical Aspects --------------------- Since the system is variable we would like ISAAC spectroscopy (71.A-0407(E)) to be taken as soon as possible before/later FORS2 observations. Special Calibration Information ------------------------------- Spectrophotometric standard taken during the night in bin 2x2 is OK. Bin 1x1 => Need of the corresponding Flat Field, Dark, bias, Arcs. See OBs relative to them if necessary. The exposure time have been multiplied by 4 comparing to bin 2x2. ToO Information --------------- NA Pre-Imaging Requirements ------------------------ NA OB Information ============== List of Science OBs with Associated Finding Charts -------------------------------------------------- Total Number of Submitted Science OBs: 3 Total Number of Submitted Finding Charts: 2 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 4 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y/N/NA] Y If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y/N/NA] NA Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y/N/NA] Y [FORS only] Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [Y/N/NA] Y [FORS only] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [Y/N/NA] Y [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] NA [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page ? [Y/N/NA] NA [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA] NA [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] NA [WFI only]Are your finding charts 34 arcmin x 34 arcmin? [Y/N/NA] NA If you answered "NO" to any of these questions, please revise your OBs *before* submission.