README Template 70.1 ESO Programme ID: 70.D-0652(A) Principal Investigator: GianLuca Israel Contact Person Name: GianLuca Israel Contact Person E-mail Address: gianluca@mporzio.astro.it Contact Person Telephone Number: +39-06-94286437 Instrument: FORS1 OPC Priority Class: A OPC Approved Total Execution Time: 22.5h Estimated Total Execution Time (including overheads): 22.5h README File Submission Date: 2 August 2002 Program Description =================== General Overview ---------------- This is an imaging program consisting of 5 sub-runs of 4.5h each (uninterrupted). Each sub-run is made up by 3 OBs: 1 OB for the target (OB name RXJ0806*-n, where n=1,2,3,4,5 represents the number of the sub-run) and 2 OBs for photometric standard (RU152*-n, where again n=1,2,3,4,5). We submitted OBs for a total execution time of 22.5hr (5x4.5h). R is the first filter to be used followed by I. An additional comment on the pointing and the finding chart: A non-standard read out mode (ABCD, 2x2) used (see also below) in order to minimise the time gap between exposures. There are 2 OBs (for each sub-run) for the standard Rubin152 (coordinates have been taken form the FORS1-VLT WEB page for standards), which should be carried out at the beginning and at the end of each sub-run. Exposures should be checked right after executing then (see also Waiver 70.D-0652A.02) Waiver Request Summary ---------------------- We have requested to use a non standard read out mode (ABCD nodes, 2x2 rebinning). Waiver ID: 70.D-0652A.01 . We have also requested to perform each 4.5h sub-run without interruptions in order rely upon a larger time interval (Waiver ID: 70.D-0652A.02). Moreover we requested two uninterrupted and contiguous half nights for the first two sub-runs (see also below, Waiver ID: 70.D-0652A.02). We also requested to carry out the standard OBs during the same night of target OBs (this in consideration of the fact we use a non-standard FORS1 read out mode, Waiver ID: 70.D-0652A.02). Finally we requested to modify the standard OB exposure times according to the sky condition at that moment (Waiver ID: 70.D-0652A.02). Critical Observing Condition Constraints ---------------------------------------- None Time Critical Aspects --------------------- First night of observation should be between the 8th and 12th of Dicember (this period has been checked with the usg team). Second night must be the night after the first sub-run (IMPORTANT) in order to phase the timing of the two observations and rely upon a sufficient accurate period measurement for the next (30 days after) sub-run. In the case of scheduling problem for the first and second night please contact the PI as soon as possible. R is the first filter to be used during each of the five pointings to be scheduled as follow: 0day + 1days (tolerance 0days) + 30days (tol. -7 / +7days) + 30days (tol. -10 / +10days) + 30days (tol. -10 / +10days). IMPORTANT: when in doubt or in presence of scheduling conflict, we request to anticipate (within the above given range of days) the single pointing instead of postponing it. In anycase we would like to be advised on the pointing dates and changes (as soon as they become known; see below for the e-mail contact). The 4.5h sub-run observations should be without interruptions. In case of exposure gaps (during the execution of sub-run OBs) due to technical or whether problems, we ask to extend the observations beyond the nominal 4.5h of execution time to compensate for the time lost. IN ANY CASE SUB-RUNS WITH AN EXECUTION TIME LESS THAN 3.5H ARE USELESS (FOR THE TIMING PURPOSE OF THE PROPOSAL) AND WE WILL ASK TO EXECUTE AGAIN THE WHOLE SUB-RUN OBs DURING AN OTHER NIGHT WITHIN THE TOLERANCE INTERVAL. NOTE THAT IN THE UNLUCKY CASE THAT IT WILL NOT BE POSSIBLE TO CARRY OUT A SUB-RUN WITHIN THE TOLERANCE INTERVAL, CONTACT ASAP THE PI IN ORDER TO PLAN THE NEW STRATEGY. Standards should be carried out during the same night of the target OBs. Since we deal with a relatively faint object we ask to avoid the days around the full moon (or at least the part of nights during which the moon is present or close to the object). 8.5h XMM observation has been accepted in order to check, among other things, the optical/X-ray peak phase-shift stability with respect to the VLT/Chandra simultaneous observations carried out on November 2001. In the case the XMM pointing will be scheduled during the ESO period 70 we would like to request a (nearly)-simultaneous (within 1-2 nights depending on the accuracy of the ephemeris at the moment of the X-ray observations) VLT observation. Note that the XMM Cycle 4 will start on September 2002. IN ANY CASE THE FIRST TWO VLT SUB-RUNs CAN NOT BE TRIGGERED BY XMM. Below are the e-mail addresses and phone numbers of the people which can take decisions concerning this observations. The second person can be contacted in the case of not availability of the PI. GianLuca Israel - gianluca@mporzio.astro.it uff +39-06-94286437 home +39-06-5747493 Feel you free to write or call the PI whenever you want (even during nightime). Gianni Marconi - gmarconi@eso.org uff +56-24633118 Special Calibration Information ------------------------------- Bias and RI-filter sky flats in ABCD, 2x2 are needed and OBs included. ToO Information --------------- Not applicable Pre-Imaging Information ----------------------- No pre-imaging is required for this programme. Note that the finding chart attached to the OBs is based on a FORS1 observation of the target. OB Information ============== List of Science OBs with Associated Finding Charts -------------------------------------------------- Total Number of Submitted Science OBs: 5 Total Number of Submitted Finding Charts: 1 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Number of Submitted Calibration OBs: 10 OB Compliance Checks ==================== Y = Yes, N = No, NA = Not Applicable Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages [Y]? Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [NA] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [NA]? Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages [NA]? If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars [NA]? [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page [NA]? [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA]? If you answered "NO" to any of these questions, please revise your OBs *before* submission. Destination Address for Data Products ===================================== GianLuca Israel Osservatorio Astronomico di Roma Via Frascati 33 I-00040 Monteporzio Catone ITALY *************************************** DO NOT WRITE BELOW THESE LINES!!!!!!!!! ***************************************