README Template 70.1 ESO Programme ID: 70.C-0726(A) Principal Investigator Name: ARPIGNY Claude Principal Investigator E-mail Address: Claude.Arpigny@ulg.ac.be Principal Investigator Telephone Number: +56 2 4633065 Instrument: UVES OPC Priority Class: A OPC Approved Total Execution Time: 18h00 Estimated Total Execution Time (including overheads): 03h30 (only a set of OB because ToO) README File Submission Date: 28/08/02 Programme Description ===================== General Overview ---------------- This is a ToO program to obtain high resolution (70.000) and high S/N (500) spectra of a sample of a few (3 to 5) rather bright comets (V < 9.0) to determine their 12C/13C and 14N/15N isotopic ratios. We are using only one setting (DIC#1). The main difficultiy of the program is to update the OBs with : - the coordinates (from ephemeris) - the blind offsets (to put the slit at a given distance from the nucleus, see below) - the differential tracking rates (from ephemeris) - the ROT angle (computed from the ephemeris by us) - the exposure time All these informations will be provided during the ToO activation. UVES SETUP : ------------ Only one setting is used : DIC#1 CD#2 (390nm) + CD#3 (564nm) Slit width of 0.45" Slit fixed on the SKY + ADC ROT = to be determined for each comet SLIT POSITIONING : ---------------- To avoid the strong dust continuum from the comet nucleus the slit has to be put about a few arcsec away from the nucleus in the tail direction and perpandicular to it (SKY+ADC mode has been chosen). To achieve this we will provide : - the RA and DEC offsets from the nucleus (blind offsets) - the ROT angle (computed from the PA given in the ephemeris) So no special intervention from the astronomer is needed (except to fill the OBs with these values) These informations will of course be updated for each comet. FINDING CHARTS : --------------- No FC TARGET COORDINATES: ------------------- The ephemeris of each comet will be provided in due time and its coordinates will have to be filled in the OB, just before the observations. Be carreful that comets are fast moving objects and can go out of the UVES slit viewer field of view in less than 15 minutes. DIFFERENTIAL TRACKING RATES: --------------------------- They will be given in the ephemeris (with the proper units, "/sec) and need to be entered in the proper field of the OBs. They are changing only very slightly so they do not need to be adjusted during the same night. Waiver Request Summary ---------------------- None Critical Observing Condition Constraints ---------------------------------------- None Time Critical Aspects --------------------- As the magnitude of a comet is changing rapidly when it is at its brightest luminosity, all the observations of a given comet (~5 hours at the most), should be done in less than one week (and if possible during consecutive nights). Special Calibration Information ------------------------------- As we want to reach the highest S/N and best wavelength calibration, we need a set of standard day calibrations after each run. ToO Information --------------- That's a ToO program ! Pre-Imaging Information ----------------------- None OB Information ============== As we are using always the same configuration and setting we have provided only one OB per target (assuming we will have 4 targets). But as the targets are not yet know these 4 OBs are in fact identical. The typical exposure time of an OB will be around 45 min and the OB will need to be repeated at least 3x (in less than one week) for a given comet. The exact information (how long and how many times the OB has to be executed) will of course be provided during the activation of the ToO and depends of the brightness of the comet. List of Science OBs with Associated Finding Charts -------------------------------------------------- Total Number of Submitted Science OBs: 4 Total Number of Submitted Finding Charts: 0 OB name ---------------- TOO_MOV_cometW_01 TOO_MOV_cometX_01 TOO_MOV_cometY_01 TOO_MOV_cometZ_01 List of Calibration OBs with Associated Science OBs --------------------------------------------------- None Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== Y = Yes, N = No, NA = Not Applicable Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages [Y/N/NA]? Y Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [Y/N/NA] NA Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [Y/N/NA]? NA Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages [Y/N/NA]? Y If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars [Y/N/NA]? NA [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page [Y/N/NA]? NA [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA]? NA If you answered "NO" to any of these questions, please revise your OBs *before* submission.