README Template 70.1 ESO Programme ID: 70.C-0477(B) Principal Investigator Name: Artie Hatzes Principal Investigator E-mail Address: artie@tls-tautenburg.de Principal Investigator Telephone Number: +49-36427-863-51 Instrument: UVES OPC Priority Class: A OPC Approved Total Execution Time: 7.5hrs Estimated Total Execution Time (including overheads): 7.5hrs README File Submission Date: Programme Description ===================== General Overview ---------------- These are spectroscopic observations with UVES using the UVES_red_obs_exp 600 standard setting and the iodine absorption cell. The cell is used for precise radial velocity measurements and is placed in the the light path during an observation. We are making observations of the same stars for two epochs. Thus the target list for runs A and B are the same. We only need one template spectrum (star without iodine) for the entire period 70, so these are divided equally between run A and B. The naming convention for the OBs are "objectname_type_n" where objectname is the object, type is either "iodine" or "template" and n is the number of observation for that object (over the runs A and B). "template" refers to an observation without the iodine cell "iodine" refers to an observation with the iodine cell in place. ******* IMPORTANT *************************************************** As part of the reduction procedure we need to deconvolve the instrumental profile from the template spectrum (spectrum of star without iodine). To do that requires an observation of a hot star (HR 948) taken through the cell (the standard iodine spectrum through the flat is insufficient for this). Thus, when you take a template spectrum you should also observe the hot star HR 948 once through the cell and once without (through the cell has the highest priority). **** If you do not take a template spectrum on a given night do not take a spectrum of the calibration hot star (HR 948), I repeat do not waste an OB observing on HR 948. That observation would be useless and an OB will be wasted!! **** Please note, that if several template spectra of different stars are taken on the same night, then only one series of HR 948 (through cell and without cell) is needed. If you can, try to take several template observations in the same night as this is more efficient and requires less OBs. Note that the first time a star is observed it makes sense to take a sequence with the cell and then one without (this will save acquisition time). If you take several template spectra a night, then you only need one HR948_iodine and one HR948_template. In this case the number of of HR948_iodine OBs should be enough for all the templates In the worst case scenario, if you only take one template spectrum a night you will not have enough HR948_iodine OBs. In this case it is not necessary to take the rest of the template stars (star without iodine) since there will be no more HR948_iodine OBs to accompany them. In this case the template can be made in the next period we apply time for, since this is a several year project. The templates can be taken at any time during the program. ---------------------- Critical Observing Condition Constraints ---------------------------------------- This project can be carried out under reasonably poor seeing conditions. Time Critical Aspects --------------------- These observations should be made near the end of the semester, preferably in Jan. (The Hyades are not well accessible if you go too late in Feb, Mar. but if you can acquire the objects this late in the season, then that is ok.) Special Calibration Information ------------------------------- Just standard calibration is needed (ThAr, Flat, Bias, Iodine spectrum (i.e. flat lamp taken through the iodine cell). *** It is important that along with the other calibrations that an iodine spectrum is taken using the flat lamp. *** ToO Information --------------- Pre-Imaging Information ----------------------- OB re using image slicer #3. Slit-viewer should be used to put the object into the image slicer. This is a crowded field so the finding charts will definitely be needed. Information ============== List of Science OBs with Associated Finding Charts -------------------------------------------------- Total Number of Submitted Science OBs: 22 Total Number of Submitted Finding Charts: 13 Even though I have submitted finding charts they should not be needed since all of these stars are bright. The object should be the brightest star in the field. OB: Finding Chart HR 948_iodine_3-5 None, 6 mag star! HR 948_template_calib_4 None, 6 mag star! vB25_iodine_2 70.C-0477A.001.ps vB25_template 70.C-0477A.001.ps HD284930_iodine_2 70.C-0477A.002.ps HD284930_template 70.C-0477A.002.ps HD285837_iodine_2 70.C-0477A.003.ps HD286589_iodine_2 70.C-0477A.004.ps HD286789_iodine_2 70.C-0477A.005.ps vB10_iodine_2 70.C-0477A.006.ps vB10_template 70.C-0477A.006.ps vA529_iodine_2 70.C-0477A.008.ps vA529_template 70.C-0477A.008.ps vB99_iodine_2 70.C-0477A.009.ps vB99_template 70.C-0477A.009.ps vB87_iodine_2, 70.C-0477A.010.ps vB87_template 70.C-0477A.010.ps vb76_iodine_2 70.C-0477A.011.ps HD284552_iodine_2 70.C-0477A.012.ps BD+04810_iodine_1 70.C-0477A.013.ps List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: OB Compliance Checks ==================== Y = Yes, N = No, NA = Not Applicable Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages [Y]? Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [NA] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [NA]? Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages [Y]? If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars [NA]? [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page [NA]? [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA]? If you answered "NO" to any of these questions, please revise your OBs *before* submission.