README Template 69.1 ESO Programme ID:69.D-0435(A) Principal Investigator Name:Glicenstein Principal Investigator E-mail Address:glicens@hep.saclay.cea.fr Principal Investigator Telephone Number:+33-1-6908-9814 Instrument: FORS2 OPC Priority Class: A OPC Approved Total Execution Time: 3 hours Estimated Total Execution Time (including overheads): 3:00:00 or less (depending on the scenario) README File Submission Date: 08 Mars 2002 Programme Description ===================== General Overview ---------------- This programme aims at taking advantage of the caustic effect, which takes place in certain gravitational microlensing events, to spatially resolve the disk of the source star. One can thus investigate in a unique way the variations of the source star atmospheric properties while the caustic lines sweeps across the disk, all the way from the centre of the disk to the limb. Waiver Request Summary ---------------------- None Critical Observing Condition Constraints ---------------------------------------- No critical constraints. Time Critical Aspects --------------------- The caustic crossing (level II) alerts are provided by the microlensing search teams. They are usually published a few days before the events. The exact time of cautic crossing can only be predicted one or two days before, with a precision of about one hour. The most important observations (TOO-B) have to be made during the caustic crossing, and, in the case of a "fast" (a few hours long) event, the coordination with the microlensing teams is needed in order to catch this critical time. Depending on the microlensing event, the total time taken by the caustic line to cross the source star disk may be as short as a few hours or as long as a few days. Therefore, we have prepared OBs dealing with different observation scenarios. One of these scenarios, is based on OBs labelled F (Fast_caustic_crossing), one on OBs labelled S (Slow_caustic_crossing), and blocks with 5 minutes exposures in the event of a high luminosity smooth peak allowing a fast sampling strategy (P blocks). When the caustic-crossing characteristics will be known, we will pick up the appropriate scenario (cf. the OB information below). If it turns out that the relevant scenario is the Fast one, then all the OBs but the first one (TOO-A, which should be executed before the caustic crossing) should be executed during a single night. If the proper scenario turns out to be the Slow one, then we will request that the OBs be spread over 2 or perhaps 3 nights. As before, the first OB (TOO-A) should be executed before the caustic crossing. Special Calibration Information ------------------------------- No special calibration is requested. ToO Information --------------- As indicated above, we have prepared 2 scenarios which will be selected according to the expected duration of the crossing. The sequence of OBs to be executed will be : Scenario "Fast": TOO-A TOO-F1 TOO-F2 TOO-F3 TOO-C (2:50:30) Scenario "Slow": TOO-A TOO-S1 TOO-S2 TOO-S3 TOO-C (2:59:30) If a smoothed peak occurs, TOO-P sequences could be preferred to one of the TOO-F or TOO-S. Pre-Imaging Information ----------------------- None OB Information ============== List of Science OBs with Associated Finding Charts -------------------------------------------------- TOO-A TOO-B-F1 TOO-B-F2 TOO-B-F3 TOO-B-P1 TOO-B-P2 TOO-B-P3 TOO-B-P4 TOO-B-P5 TOO-B-P6 TOO-B-S1 TOO-B-S2 TOO-B-S3 (TOO-C is a standard OB for spectro-photometric purposes). Total Number of Submitted Science OBs: 13 (but not all of them will be executed in a given scenario) + TOO-C Total Number of Submitted Finding Charts: none. The finding charts will have to be provided after the alerts. List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 1 (TOO-C) TOO-C is a standard OB for spectro-photometric purposes. OB Compliance Checks ==================== Y = Yes, N = No, NA = Not Applicable Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages [Y/N/NA]? Y Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [Y/N/NA] Y Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [Y/N/NA]? Y Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages [Y/N/NA]? NA If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars [Y/N/NA]? Y [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page [Y/N/NA]? NA [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA]? NA If you answered "NO" to any of these questions, please revise your OBs *before* submission. Destination Address for Data Products ===================================== Jean-Francois Glicenstein DSM/DAPNIA/SPP Batiment 141 Centre d'etudes de Saclay F-91191 Gif-sur-Yvette FRANCE