README Template 69.1 ESO Programme ID: 69.D-0279(B) Principal Investigator Name: Gallant Principal Investigator E-mail Address: gallant@discovery.saclay.cea.fr Principal Investigator Telephone Number: +33-1-69 08 92 61 Instrument: ISAAC OPC Priority Class: B OPC Approved Total Execution Time: 2.0 Estimated Total Execution Time (including overheads): 2.0 README File Submission Date: February 21, 2002 Programme Description ===================== General Overview ---------------- In this run we attempt to detect extended [FeII] emission from filaments in the composite SNR G21.5-0.9, by subtracting exposures in the NB_1.71 continuum filter from ones in the NB_1.64 [FeII] line filter. The two filters are sandwiched in the same OB, to ensure as closely matched observing conditions as possible. One OB is to be performed under photometric conditions along with the calibration star OB. All image acquisition is by simple preset. Waiver Request Summary ---------------------- We requested a Phase 2 Waiver to include both filters in the same OBs on February 12, 2002. I was informed on February 14, 2002 that it was granted. Critical Observing Condition Constraints ---------------------------------------- One science OB (ZERO G21.5-0.9 FeII) should be executed under photometric conditions, in conjunction with the standard star observation (CAL SAO 245532) to establish flux calibration. At H magnitude 8.612, SAO 245532 is in the mildly non-linear regime in the central pixels for DIT=3.55s and the specified seeing of 1.2". In the unlikely event that the seeing is much better than this (0.7" or better), the central pixels may actually saturate; it may be desirable not to switch on the active optics to avoid excessively sharpening the PSF. Time Critical Aspects --------------------- Special Calibration Information ------------------------------- As the narrow-band filters are not supported by the calibration plan, we provide a standard star observation OB, "CAL SAO 245532", to be executed contiguously with one of the two science OBs, "ZERO G21.5-0.9 FeII". This star is a type F8 or F9 from the list of van der Bliek et al., and is thus better suited for calibrating the 1.64 micron filter of interest here than other standard stars of known spectral type in this part of the sky, which are hotter (B8 to A3) and typically have a strong Balmer absorption line in the NB_1.64 filter bandpass. In order to observe this H=8.612 star, the minimum DIT of 3.55s is required, but as only 4 exposures are taken (NDIT=1) this does not entail a dramatic increase in overheads. Twilight flat fields will be needed in both of the narrow-band filters, but from what I understand, these should be automatically taken at the end of the night as part of the calibration plan. ToO Information --------------- Pre-Imaging Information ----------------------- OB Information ============== List of Science OBs with Associated Finding Charts -------------------------------------------------- Total Number of Submitted Science OBs: 2 (+ 1 calibration stars) Total Number of Submitted Finding Charts: 2 CAL SAO 245532 = 69.D-0279B.001.ps ZERO G21.5-0.9 FeII = 69.D-0279B.002.ps G21.5-0.9 FeII 1 = 69.D-0279B.002.ps List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 1 CAL SAO 245532 ZERO G21.5-0.9 FeII OB Compliance Checks ==================== Y = Yes, N = No, NA = Not Applicable Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages [Y]? Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [NA] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [NA]? Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages [NA]? If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars [Y]? [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page [Y]? [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y]? If you answered "NO" to any of these questions, please revise your OBs *before* submission. Destination Address for Data Products ===================================== Dr. Yves Gallant Service d'Astrophysique C.E.A. Saclay 91191 Gif-sur-Yvette Cedex FRANCE