README Template 69.1 ESO Programme ID: 69.D-0261(A) Principal Investigator Name: J.P Beaulieu Principal Investigator E-mail Address: beaulieu@iap.fr Principal Investigator Telephone Number: +33 1 44 32 81 19 (off) Instrument: OPC Priority Class: A OPC Approved Total Execution Time: 14 hours Estimated Total Execution Time (including overheads): 14 hours README File Submission Date: Programme Description ===================== General Overview ---------------- This ToO program will undertake UVES spectroscopy of a single Galactic Bulge star that is currently being magnified and resolved by a microlensing caustic. As the caustic sweeps over the star, the strentgh of athmospheric lines in the bulge star can be measured as a function of position on the stellar disk, providing a means of stellar tomography. This has already been accomplished once : with FORS in 2000 (Albrow et al 2001 ApJ 550, L173). Pre- and post-caustic data may allow separation of the source star spectrum from the lens star spectrum, and thus give the first direct detection and spectral typing of a microlens. This is a ToO program since the position of the lens can not be known in advance. This program involved a variety of timescale that are described in more details hereafter. The timescale are approximate; T=0 correspond to the second caustic crossing, wich can be predicted with precision 12-36h in advance. The caustic crossing itself is expected to last 8-24 hrs. The observations will proceed in three sections. Pre-Caustic : Star is magnified but unresolved, ~2h observation Caustic : Star magnified and resolved, ~8h observation Post Caustic : Star unmagnified and unresolved, ~4h observation Day T= -14 to -7 : The event is identified that will be undergoing a caustic crossing in the near future. The needed informations are provided to ESO with an actualised list of people authorised to activate the Observations Day T <= -5 : The Precaustic observations are requested to be executed in a period covering the next 48h. Observations will take around 2h Once the OB's are executed the spectra should be made available immediately to a person whose coordinate will be provided by the authorised activator. Day T <=-2 : We confirm here if the caustic crossing is going to be over Chilean longitudes and send the details of the observations for the caustic crossing Day T <=12hrs : The exact timing of the crossing of the caustic is known. The go ahead to execute the caustic crossing observations is given by one of the authorised activator. The 8h of observations will have to be executed in one night or in cases of exceptionnaly long crossing over 2 nights Day T >= 1 : The post-caustic OB's have to be executed in a period of 7days after the crossing and will take between 2 and 4 hrs Only one configurations of UVES will be used (red arm) with two central wavelength. Waiver Request Summary ---------------------- A waiver was submitted to have OB's lasting more than one hrs and using two different setup of the instrument (red arm only) in the same OB's. The waiver was granted on the 11th of February. Critical Observing Condition Constraints ---------------------------------------- Observations during the crossing should be taken in any conditions. Time Critical Aspects --------------------- Observations must be timed with the caustic crossing. The timing will be determined idependently from our team continuous photometric monitoring from a network of small southern telescopes and the ESO 2.2m. Pre-caustic spectra can be taken any time in a 2-3 days window. Caustic spectra must be taken in one single night, which can be determined 12-36 hours in advance. Post-caustic spectra can be taken any time during a 7 day window. The most likely period for a caustic alert is May to August. Special Calibration Information ------------------------------- No special request for calibrations are needed. ToO Information --------------- This is a ToO program Authorized contact personnel: Dr Stephane Brillant European Southern Observatory +56 2 4633120 (off) +56 2 2114232 (home) +56 9 4360334 (cell) sbrillan@eso.org Dr Jean-Philippe Beaulieu Institut d'Astrophysique de Paris +33 1 46 27 08 03 (home) +43 1 40 51 779 (home number 2 in Austria) +33 1 44 32 81 19 (off) +33 6 03 98 73 11 (cell) beaulieu@iap.fr Dr Christian Coutures European Southern Observatory +56 2 4633151 (off) ccouture@sc6.sc.eso.org Dr Penny D. Sackett She will be moving from Holland to Australia in April. We do not have yet her contact numbers in Australia. psackett@astro.rug.nl. An updated list of authorized person will be provided with the correct coordinate as soon as possible. Pre-Imaging Information ----------------------- No pre imaging needed OB Information ============== Since the target is unknow for now, the finding charts will be provided at the activation of the ToO. List of Science OBs with Associated Finding Charts -------------------------------------------------- ToO_PreCaustic ToO_Caustic_1 ToO_Caustic_2 ToO_Caustic_3 ToO_Caustic_4 ToO_Caustic_5 ToO_Caustic_6 ToO_Caustic_7 ToO_Caustic_8 ToO_Caustic_9 ToO_Caustic_10 ToO_Caustic_11 ToO_PostCaustic_1 ToO_PostCaustic_2 Total Number of Submitted Science OBs: 14 Total Number of Submitted Finding Charts: 0 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== Y = Yes, N = No, NA = Not Applicable Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages [Y/N/NA]? Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [Y/N/NA] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [Y/N/NA]? Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages [Y/N/NA]? If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars [Y/N/NA]? [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page [Y/N/NA]? [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA]? If you answered "NO" to any of these questions, please revise your OBs *before* submission. Destination Address for Data Products =====================================