README Template 69.1 ESO Programme ID: 69.C-0722(A) Principal Investigator Name: Kuerster Principal Investigator E-mail Address: mkurster@eso.org Principal Investigator Telephone Number: +56-2-463-3055 Instrument: UVES OPC Priority Class: C OPC Approved Total Execution Time: 60.0 Estimated Total Execution Time (including overheads): 60.0 README File Submission Date: 27 February 2002 (revised version) Programme Description ===================== General Overview ---------------- This is the continuation of our radial velocity planet search programme studying M-dwarf stars with UVES and its iodine cell. Iodine cell observations involve OBs of different type (OBs with and without iodine cell for survey stars and OBs with and without iodine cell for calibration stars) and require special attention as to when an OB of a certain type is to be carried out. This is detailed below in "Time Critical Aspects". Waiver Request Summary ---------------------- Critical Observing Condition Constraints ---------------------------------------- Constraint set for all OBs: Seeing 2.0 Sky transparency: Variable, thin cirrus Air mass: 5.0 Fractional lunar illumination: 1.0 Moon angular distance: 30 Time Critical Aspects --------------------- Constraints on the execution of OBs arise from the usage of the different types: OB type (1): M-dwarf OBs with iodine cell named _iodine_, e.g. Gl637_iodine_01 This type of OB will produce the radial velocity measurement for the M-dwarfs at a given time. Due to the survey nature of the programme and the search for time variability on time scales longer than a day, only one OB of this type is to be carried out per night per star. Ideally, the submitted OBs of this type should be executed as irregularly as possible for each star throughout period 69. Execution of OBs for the same star in 2 consecutive nights should be done maximally once per star. OB type (2): M-dwarf OB without iodine cell named _pure_iodine, e.g. Gl637_pure This type of OB is for six of our M-dwarfs. Only one OB of this type exists for these stars. For each of them the OB type (2) is is required for the later modelling of the star+iodine spectra (i.e. OB type (1)) which are useless without the OB type (2). We propose to schedule the OB type (2) for these stars, before any OBs of type (1) are executed. For three of our stars (Barnard, GJ433, and ProxCen) no such OB type (2) has been submitted, because it is already available from earlier UVES observations. OB type (3): Calibration B-star with iodine cell named _iodine_calstar_, e.g. HR5035_iodine_01 Execution of this type of OB must accompany the execution of any OB of type (2), immediately before or after, and is not to be used unless an OB of type (2) is executed. As there is one OB each of type (2) for six different stars, also six OBs of type (3) have been submitted. They consist of two OBs each for three different stars spanning a suitable range of right ascensions. OB type (4): Calibration B-star without iodine cell named _pure_calstar_, e.g. HR5035_pure_01 For this type of OB the same applies as for type (3). So when, and only when, and OB of type (2) is executed, also one OB each of types (3) and (4) must be executed. Special Calibration Information ------------------------------- UVES Iodine cell mode has its standard calibration set which we accept. It should look something like this: 5 Biases, 1 ThAr, 5 Flats, 5 Flats with iodine cell. Note that the iodine cell should be preheated to 70 C before use. ToO Information --------------- Pre-Imaging Information ----------------------- OB Information ============== List of Science OBs with Associated Finding Charts -------------------------------------------------- Total Number of Submitted Science OBs: 84 Total Number of Submitted Finding Charts: 0 OB-list: Barnard_iodine_01 ... Barnard_iodine_14 GJ433_iodine_01 ... GJ433_iodine_06 Gl637_ioinde_01 ... Gl637_ioinde_06 Gl637_pure Gl682_iodine_01 ... Gl682_iodine_06 Gl682_pure Gl739_iodine_01 ... Gl739_iodine_06 Gl739_pure Gl817_iodine_01 ... Gl817_iodine_06 Gl817_pure Gl821_iodine_01 ... Gl821_iodine_06 Gl821_pure Gl855_iodine_01 ... Gl855_iodine_06 Gl855_pure HR5035_iodine_calstar_01 ... HR5035_iodine_calstar_02 HR5035_pure_calstar_01 ... HR5035_pure_calstar_02 Proxcen_iodine_01 ... Proxcen_iodine_10 Psi2Aqr_iodine_calstar_01 ... Psi2Aqr_iodine_calstar_02 Psi2Aqr_pure_calstar_01 ... Psi2Aqr_pure_calstar_02 ThetaLup_iodine_calstar_01 ... ThetaLup_iodine_calstar_02 ThetaLup_pure_calstar_01 ... ThetaLup_pure_calstar_02 Finding charts: As earlier for this programme we do not submit any finding charts, which would be useless as we are observing stars that are always the brightest in the field. In every OB we provide proper motion corrected J2000 coordinates for epoch 2002.5. From previous experience we know that this ensures that the star always arrives on the UVES slit. List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== Y = Yes, N = No, NA = Not Applicable Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages [Y]? Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [NA] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [NA]? Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages [Y]? If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars [NA]? [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page [NA]? [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA]? If you answered "NO" to any of these questions, please revise your OBs *before* submission. Destination Address for Data Products ===================================== The PI will change his affiliation as of 01 May 2002. The data products shall be sent to his new address: Martin Kuerster Thueringer Landessternwarte Tautenburg Sternwarte 5 D-07778 Tautenburg Germany