README Template 69.1 ESO Programme ID: 69.C-0263(A) Principal Investigator Name: Claire Moutou Principal Investigator E-mail Address: claire.moutou@astrsp-mrs.fr Principal Investigator Telephone Number: (33 4) 91 05 59 66 Instrument: UVES OPC Priority Class: A OPC Approved Total Execution Time: 32 hours Estimated Total Execution Time (including overheads): 32 hours README File Submission Date: 30.07.2002 Programme Description ===================== This is a revised version: please see modifications in the "Time Critical Aspect" section. General Overview ---------------- We aim at VERY HIGH SIGNAL-TO-NOISE RATIO spectra of HD209458 in the red-580 setup, in search for the faint signatures of an orbiting planet during the transit of the star. - These observations are mostly time critical - Comparison targets should be observed in the described sequences - Accurate calibrations are required for the success of the project. Waiver Request Summary ---------------------- We have requested particularly long sequences of flatfield calibrations, in order not to be limited by flatfielding in the scientific achievement. Waiver request #69.C-0263A.01 has been approved on 15.02.2002. Critical Observing Condition Constraints ---------------------------------------- No special conditions are required. Time Critical Aspects --------------------- During P69, the planet transit of HD209458 will occur during these periods: (note that the transit sometimes occurs after midnight Local Time) Day/Month Observation period Priority Comment ========================================================================== 06/06 done 13/06 done 22/07 done 29/07 done 05/08 05:00-08:00 1 transit visible in totality 12/08 05:40-08:40 2 end: object low 13/09 00:30-03:30 2 beginning: object low 20/09 00:40-03:40 1 visible in totality 27/09 01:45-04:45 1 visible in totality ========================================================================== We have shared the allocated time in order to observe 5 transits among these 8, *if possible* including the "Priority 1" transits (best time sampling). 30 OBs MUST BE executed during these time slots, in sequences that last 3 hours 7min, i.e., their execution time matches the transit duration. The comparison target 18Peg should be observed 3 times during such a sequence, as well as the main target, HD209458, alternatively. Off-transit observations: off-transit OBs of HD209458 can be executed any time EXCEPT the on-transit nights. 30 off-transit OBs as well. They are identical to on-transit OBs. Special Calibration Information ------------------------------- Very high signal-to-noise ratio flatfields are required (see waiver). Please execute one calibration OB after each night where HD209458 is observed (whether a transit occured or not). Probably the integration time of the submitted OBs should be changed. The aim is a SNR larger than 1000. ToO Information --------------- Pre-Imaging Information ----------------------- OB Information ============== The OB named HD195838 can be executed any time and independently of the others! On and off-transit sequences: this is very important to get several spectra of a telluric standard in order to monitor atm. lines. Please execute the following sequences: OB name (i=1 to 10) Object ================================================== HD209458-Seqi-1 HD209458 18Peg-Seqi-1 18 Peg (telluric std) HD209458-Seqi-2 HD209458 18Peg-Seqi-2 18 Peg (telluric std) HD209458-Seqi-3 HD209458 18Peg-Seqi-3 18 Peg (telluric std) ================================================== Sequence duration (inc. overheads) : 3 hours 7 min Note on the overhead calculation: the execution time estimation is below the one computed by P2PP, because we took the following values (that we think are quite reasonable): - 6min preset overhead for the beginning of the sequence - 4min preset for the 5 following OBs (nearby+bright); this makes the difference with P2PP computation. - 1min acquisition for each OB of the sequence (bright point source) - 1min setup overhead per OB - 40 sec readout for each of the 9 exposures that is, in total, 44 min overhead per sequence (instead of 55min in P2PP). There are 10 identical sequences; 5 must be executed during on-transit nights and 5 must be executed out of these nights. The OB name should help the scheduling. In case a sequence must be interrupted, the "unbreakable" pair is: HD209458-Seqi-j + 18Peg-Seqi-j List of Science OBs with Associated Finding Charts -------------------------------------------------- No useful finding chart can be produced: targets are 6 and 7.65 magnitude in V and coordinates are precise. A neutral density filter is inserted in order to ease the acquisition. Total Number of Submitted Science OBs: 61 Total Number of Submitted Finding Charts: 0 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 10 OB Compliance Checks ==================== Y = Yes, N = No, NA = Not Applicable Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages [Y/N/NA]? Y Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [Y/N/NA] NA Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [Y/N/NA]? NA Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages [Y/N/NA]? Y If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars [Y/N/NA]? NA [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page [Y/N/NA]? NA [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA]? NA If you answered "NO" to any of these questions, please revise your OBs *before* submission. Destination Address for Data Products ===================================== Claire Moutou Laboratoire d'Astrophysique de Marseille Traverse du Siphon, Les 3 lucs 13012 Marseille FRANCE