README Template 69.1 ESO Programme ID: 69.B-0345(A) Principal Investigator Name: L. Vanzi Principal Investigator E-mail Address: lvanzi@eso.org Principal Investigator Telephone Number: 56-2-4633104 / 56-2-2632774 Instrument: ISAAC OPC Priority Class: B OPC Approved Total Execution Time: 8.0 h Estimated Total Execution Time (including overheads): 7h 59m README File Submission Date: 20 February 2002 Programme Description ===================== General Overview ---------------- This is a simple imaging programme in the K and L infrared bands. The K images are executed with the AutoJitterOffset template, the sky is taken at 200 arcsec from the source. The L images are executed with the AutoChop template, the chop is 25 arcsec in order to have the source always in the field of view. Waiver Request Summary ---------------------- Critical Observing Condition Constraints ---------------------------------------- OBs must be executed under clear sky conditions and seeing below 1.2 arcsec. Please make sure that, given the sky and seeing conditions counts are within the acceptable range for standard stars ond scientific objects and that no saturation occurs. Time Critical Aspects --------------------- Special Calibration Information ------------------------------- Standard calibrations are required including Flatfields and standard stars. In addition to the standard stars normally observed for the calibration plan we require that at least one standard star in each filter is observed imediately before or after the scientific observations. OBs for these calibrations are provided by us. Since the K observations are short we assume that they will be executed all in one or two shots, for this reason we provide OBs for two standard stars in K band. Observations in L are longer and more likely to be splitted on different nights, we provide OBs for 3 standard stars in this case. Should the observations be splitted over more than 2 or 3 nights we will relay on the standard calibrations and Zp provided as part of the calibration plan. ToO Information --------------- This is not a ToO programme. Pre-Imaging Information ----------------------- No pre-imaging is required for this programme. OB Information ============== List of Science OBs with Associated Finding Charts -------------------------------------------------- Total Number of Submitted Science OBs: 12 Total Number of Submitted Finding Charts: 6 IIZw40_L = 69.B-0345A.001.ps IIZw40_K = 69.B-0345A.001.ps NGC5253_L = 69.B-0345A.002.ps NGC5253_K = 69.B-0345A.002.ps Pox36_L = 69.B-0345A.003.ps Pox36_K = 69.B-0345A.003.ps Tol35_L = 69.B-0345A.004.ps Tol35_K = 69.B-0345A.004.ps Tol3_L = 69.B-0345A.005.ps Tol3_K = 69.B-0345A.005.ps UM462_L = 69.B-0345A.006.ps UM462_K = 69.B-0345A.006.ps List of Calibration OBs with Associated Science OBs --------------------------------------------------- Number of Submitted Calibration OBs: 5 CAL_std_hd77281_L good for IIZw40_L, Tol3_L CAL_std_hd106965_L good for Tol3_L, UM462_L, Tol35_L, Pox36_L, NGC5253_L CAL_std_hd106965_L_0 same as previous one CAL_std9150_K good for Tol3_K, UM462_K, Tol35_K, Pox36_K, NGC5253_K CAL_std9121_K good for IIZw40_K, Tol3_K OB Compliance Checks ==================== Y = Yes, N = No, NA = Not Applicable Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages [Y]? Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [NA] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [NA]? Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages [NA]? If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars [NA]? [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page [NA]? [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y]? If you answered "NO" to any of these questions, please revise your OBs *before* submission. Destination Address for Data Products ===================================== Dr. Leonardo Vanzi ESO Alonso de Cordova 3107 Vitacura, Santiago CHILE