README Template 69.1 ESO Programme ID: 69.A-0513(A) Principal Investigator Name: Dimitra Rigopoulou Principal Investigator E-mail Address: dar@mpe.mpg.de Principal Investigator Telephone Number: 089-30000-3392 Instrument: FORS1 OPC Priority Class: C OPC Approved Total Execution Time: 10hrs Estimated Total Execution Time (including overheads): 9:58 README File Submission Date: 05-AUG-2002 Programme Description ===================== We wish to obtain Multi-Object Spectroscopy of high-redshift targets in the Hubble Deep Field South. Our observations consist of two masks one using the blue (G300V) and the other the red (G300I+11) grisms. The aim is to get spectra covering the full 3000-11000 A regime providing us with a wealth of emission/absorption lines (eg. MgII, [OII], [OIII] etc). As pre-image we have used a FORS1 image taken from the VLT science archive (FORS2.2000-07-27T03:38:37.190.fits). The mask/slits have been designed using FIMMS on this image. We use 1 arcsec slit widths for both grisms. General Overview ---------------- The program includes 10 OBs, 7 using the blue and 3 using the red grism Waiver Request Summary ---------------------- Critical Observing Condition Constraints ---------------------------------------- our observing condition constraints are summarized in the CS part of the OB. Our observations could be excecuted under seeing of ~1 arcsec, with thin cirrus present and during grey time. Time Critical Aspects --------------------- the proposed observations are NOT time critical. Special Calibration Information ------------------------------- We request a set of standard calibration files including flats (screen or twilight flats), wave cals and darks. Also we would like to request observations of a spectrophotometric standard chosen from the suite of SPECPHOT standard stars routinely used by FORS. ToO Information --------------- Pre-Imaging Information ----------------------- no pre-imaging required--we have used FORS1 archival data OB Information ============== We have submitted 10 OBs, 7 using the GRIS300V grism and 3 using the GRIS300I+11 grism 1) GRIS300V corresponding OBs: brightst_blue1,2,3,4,5,6,7 OBs brightst_blue1,2,3,4,5,6,7 are all identical containing a MOS acquisition template, a through slit image template and the mos spectroscopy template. Each OB lasts for 1 hour. The total exposure time of brightst_blue1 to 7 is 5.67 hours and excecution time is ~7 hours. 2) GRIS300I+11 corresponding OBs: isocam_red1,2,3 OBs isocam_red1,2,3 are all identical containing a MOS acquisition template, a through slit image template and the mos spectroscopy template. Each OB lasts for 1 hour. Each OB consists of 2 exposures each lasting 1440 sec and are separated by 2 arcsec along the slit. The total exposure time of isocam_red1,2,3 is about 2.4 hours and excecution time is ~3 hours. List of Science OBs with Associated Finding Charts -------------------------------------------------- Total Number of Submitted Science OBs: 10 Total Number of Submitted Finding Charts: 4 69.A-0513A.001.ps corresponds to OBs brightst_blue1,2,3,4,5,6,7 69.A-0513A.002.ps is a magnified version of 69.A-0513A.001.ps 69.A-0513A.003.ps corresponds to OBs isocam_red1,2,3 69.A-0513A.004.ps is a magnified version of 69.A-0513A.001.ps List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== Y = Yes, N = No, NA = Not Applicable Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages [Y]? Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [Y] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [Y]? Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages [NA]? If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars [NA]? [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page [Y/N/NA]? [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA]? If you answered "NO" to any of these questions, please revise your OBs *before* submission. Destination Address for Data Products ===================================== Dimitra Rigopoulou MPE Giessenbachstrasse 85748 Garching