README Template 68.1 ESO Programme ID: 68.B-0057(A) Principal Investigator: I. Appenzeller Contact Person Name: Jochen Heidt Contact Person E-mail Address: jheidt@lsw.uni-heidelberg.de Contact Person Telephone Number: +49 - 6221 - 509204 Instrument: FORS2 OPC Priority Class: A OPC Approved Total Execution Time: 3.5h Estimated Total Execution Time (including overheads): 3.3h README File Submission Date: 3.8.2001 Programme Description ===================== General Overview ---------------- In the following we describe the OBs for the 3.5h assigned service mode observations for programme 68.B-0057(A). Science exposures total 2.75h in two setups (one short setup lasting 45 min and one long setup lasting 2h splitted in 3 * 40 min). Including overheads we estimate a total execution time of 3.3h. The host galaxy of OJ 287 and (companions) galaxies in the field of OJ 287 shall be observed via MOS. The shorter setup (45 min) shall cover brighter (companion) galaxies in the field of OJ 287. For that purpose the OB "sciMOS oj 287_short" is provided. The long setup covers the host galaxy of OJ 287 via off-nuclear spectroscopy as well as fainter (companion) galaxies in the field. For higher scheduling flexibility the 3 identical science OBs "sciMOS oj287_long_1","sciMOS oj287_long_2" and "sciMOS oj287_long_3" are provided. Each OB holds a single exposure of 40 min. Telescope time can be saved by observing the three OBs of this setup back to back (and thus skipping the aquisition for OB "long_2" and "long_3"). Goal: Determine redshift of the host galaxy of OJ 287 and companion galaxies in the field. Note: This is a GTO programme (GTO13). Waiver Request Summary ---------------------- none Critical Observing Condition Constraints ---------------------------------------- Sky should be clear and dark throughout all the observations, seeing <=0.8" Time Critical Aspects --------------------- none Special Calibration Information ------------------------------- We have submitted calibration OBs to obtain flatfields and wavelength calibrations for each of our MOS Setups. They are identical for the setups long_1, long_2 and long_3! In case the science OBs for the long setup are executed during one night, one calibration OB for this setup is sufficient. Otherwise one calibration OB should be should be executed after each night. One spectrophotometric flux standard for each setup should be observed at least during one night when a science OB is executed. This can be well done within the ESO standard calibration plan. Therefore no special calibration OBs were provided. Its mandatory to use the grism/filter used for the MOS-Setups (300V+20/GG435+81). ToO Information --------------- This is not a ToO programme Pre-Imaging Information ----------------------- No pre-imaging required. OBs are based on pre-images done with FORS1. OB Information ============== List of Science OBs with Associated Finding Charts -------------------------------------------------- Total Number of Submitted Science OBs: 4 Total Number of Submitted Finding Charts: 6 Setup 1 (short): ---------------- sciMOS oj287_short = 68.B-0057A.001.ps, 68.B-0057A.002.ps, 68.B-0057A.003.ps Setup 1 (long): ---------------- sciMOS oj287_long_1 = 68.B-0057A.004.ps, 68.B-0057A.005.ps, 68.B-0057A.006.ps sciMOS oj287_long_2 = 68.B-0057A.004.ps, 68.B-0057A.005.ps, 68.B-0057A.006.ps sciMOS oj287_long_3 = 68.B-0057A.004.ps, 68.B-0057A.005.ps, 68.B-0057A.006.ps The three OBS for this setup are identical (to allow flexiblle scheduling, see above). List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 4 Setup 1 (short): ---------------- calMOS oj287_short Setup 1 (long): ---------------- calMOS oj287_long_1 calMOS oj287_long_2 calMOS oj287_long_3 OB Compliance Checks ==================== Y = Yes, N = No, NA = Not Applicable Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages [Y]? Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [Y] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [Y]? Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages [NA]? If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars [NA]? [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page [NA]? [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA]? If you answered "NO" to any of these questions, please revise your OBs *before* submission. Destination Address for Data Products ===================================== Dr. Jochen Heidt Landessternwarte K"onigstuhl 69117 Heidelberg Germany *************************************** DO NOT WRITE BELOW THESE LINES!!!!!!!!! ***************************************