README Template 68.1 ESO Programme ID:68.A-0617(A) Principal Investigator: Fontana Adriano Contact Person Name: Fontana Adriano Contact Person E-mail Address: fontana@mporzio.astro.it Contact Person Telephone Number: ++39-06-94286456 Instrument: FORS1 OPC Priority Class: A OPC Approved Integration Time: 18h Estimate Total Execution Time (including overheads): 18h README File Submission Date: 10/8/2001 Programme Description ===================== FORS1 UBVI Multicolor imaging in the NTT Deep Field with jitter technique.. General Overview ---------------- I requested 4 different filters - UnetsBVI. Each band has been divided into several OB. Only one OB for each band is required to be in photometric conditions. The relevant OBs are named ZERO-xxx In addition, I have pepared a set of OB to perform a special calibration in the U and B bands. The relevant OBs are named ZERO-CAL-xxx, and their TOTAL execution time is 1hr. See details below. I have prepared a total of 20 OB to carry on the whole program. The total execution time is 10 min longer than the totally allocated time (18hr). Since nearly all the OB refer to a single pointing, I assume that this short excess will be largely compensated by the skipping some of the target acquisition process when OBs will executed. In any case, I explicitely allow you to cut the exposure time of some OBs in case the total execution time is longer than the allocated time. The finding chart has been created using a FORS image of the field in the I band. Waiver Request Summary ---------------------- Critical Observing Condition Constraints ---------------------------------------- About seeing in the U band: I have applied to all OBs the seeing limit of 0.8" as requested in the proposal. I understand that in the U band this limit may be difficult to match over 6 hr of total exposure. Since it is not entirely clear whether the condition set relates to the seeing as measured from the seeing monitor (as I argue happens while executing the observations) or as measured on the images, I have left 0.8" as condition but I specify that I am ready to accept images up to 1" in the U band (only!). Time Critical Aspects --------------------- #1# I have prepared a set of 4 OBs designed to calibrate the field in the U and B filters. There are 3 OBs for std stars + 1 field of the NTTDF, for a total execution time of 1hr. Two std stars have RA (09:57 and 10:47) smaller than the NTTDF (12:02), the third one larger (13:23). These OBs SHOULD BE EXECUTED SEQUENTIALLY, and such that the airmass of the NTTDF lays within those of the std fields, so that I can derive a good extinction curve. The names of the OBs are ZERO-CAL-fieldname. The std fields are taken from the list on the ESO WEB page. Exptime has been defined after browsing the ESO archive for the same fields. #2# The U observations are broken into 6 different OBs, with only 4 exposures each. Since I need a large number of images with different pointings to superflat the images, OB should be executed in consecutive pairs: NTTDF_U_1of6 immediately followed by NTTDF_U_2of6 NTTDF_U_3of6 immediately followed by NTTDF_U_4of6 NTTDF_U_5of6 immediately followed by NTTDF_U_6of6 The same procedure should be applied to B images, with NTTDF_B_1of4 immediately followed by NTTDF_B_2of4 NTTDF_B_3of4 immediately followed by NTTDF_B_4of4 Special Calibration Information ------------------------------- See point #1# above. All fields are standard landolt field taken from the list on the ESO WEB page. Exptime has been taken browsing the ESO archive for the same fields. The set of 4 OBs are name ZERO-CAL-xxxx ToO Information --------------- Pre-Imaging Information ----------------------- OB Information ============== List of Science OBs with Associated Finding Charts -------------------------------------------------- ZERO-NTTDF_U_1of6 \ .. possibly executed sequentially NTTDF_U_2of6 / NTTDF_U_3of6 \ .. possibly executed sequentially NTTDF_U_4of6 / NTTDF_U_5of6 \ .. possibly executed sequentially NTTDF_U_6of6 / ZERO-NTTDF_B_1of4 \ .. possibly executed sequentially NTTDF_B_2of4 / NTTDF_B_3of4 \ .. possibly executed sequentially NTTDF_B_4of4 / ZERO-NTTDF_V_1of3 NTTDF_V_2of3 NTTDF_V_3of3 ZERO-NTTDF_I_1of3 NTTDF_I_2of3 NTTDF_I_3of3 ZERO-CAL-NTTDF_U_B \ ZERO-CAL-PG1047 \ .. to be executed sequentially or at ZERO-CAL-PG1323 / least within a single photometric night. ZERO-CAL-SA101 / 68.A-0617A.001.ps Finding chart for NTTDF (taken from a FORS image) 68.A-0617A.002.ps Finding chart for SA101 68.A-0617A.003.ps Finding chart for PG1047 68.A-0617A.004.ps Finding chart for PG1323 Total Number of Submitted Science OBs: 20 Total Number of Submitted Finding Charts: 1 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== Y = Yes, N = No, NA = Not Applicable Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages [Y]? Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [Y] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [NA]? Did you submit the mandatory calibration OBs for each FORS MOS mask setup [NA]? Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages [NA]? If you answered "NO" to any of these questions, please revise your OBs *before* submission. Destination Address for Data Products ===================================== Fontana Adriano Osservatorio Astronomico di Roma Via Frascati 33 00040 Monte Porzio Catone Rome ITALY *************************************** DO NOT WRITE BELOW THESE LINES!!!!!!!!! ***************************************