README Template 68.1 ESO Programme ID: Principal Investigator: I. Appenzeller Contact Person Name: Doerte Mehlert or Jochen Heidt or Stefan Noll Contact Person E-mail Address: dmehlert@lsw.uni-heidelberg.de or jheidt@lsw.uni-heidelberg.de or snoll@lsw.uni-heidelberg.de Contact Person Telephone Number: +49 6221 509203 (Doerte Mehlert) +49 6221 509204 (Jochen Heidt) +49 6221 509203 (Stefan Noll) Instrument: FORS2 OPC Priority Class: A OPC Approved Total Execution Time: 10.0h Estimated Total Execution Time (including overheads): 10.0h README File Submission Date: 13.08.2001 Programme Description ===================== General Overview ---------------- In the following we describe the OBs for the 10 hours assigned service mode observations with FORS2 for this program. Science exposures total 8h in two setups (4h per setup, each setup split in 5 * 2880 sec). The total execution time including overhead time is 9h55s (according to the p2pp executing time estimator). The FORS-Deep-Fieldwill be observed with two MXU setups. For higher scheduling flexibility the 5 identical science OBs "sciMXU FDF-A-1", "sciMXU FDF-A-2", "sciMXU FDF-A-3", "sciMXU FDF-A-4", "sciMXU FDF-A-5" for setup A and "sciMXU FDF-B-1", "sciMXU FDF-B-2", "sciMXU FDF-B-3", "sciMXU FDF-B-4", "sciMXU FDF-B-5" for setup B are provided. Each OB holds a single exposure of 2880 sec. Telescope time can be saved by observing the 5 OBs of each setup back to back (and thus skipping the aquisition for OB "2" to "5"). goal: derive properties of the stellar population of high-z galaxies from their spectra. Note: This is an GTO-programme (GTO01) Waiver Request Summary ---------------------- none Critical Observing Condition Constraints ---------------------------------------- Sky should be clear throughout all the observations, seeing <=1.0" Time Critical Aspects --------------------- none Special Calibration Information ------------------------------- We have submitted calibration OBs to obtain flatfields and wavelength calibrations for each of our MXU Setup. They are identical for each setup! In case the science OBs pet setup are executed during one night, one calibration OB for this setup is sufficient. Otherwise one calibration OB should be executed after each night. Two spectrophotometric flux standard for each setup should be observed at least during one night when a science OB is executed. This can be well done within the ESO standard calibration plan. Therefore no special calibration OBs were provided. Its mandatory to use the grism/filter used for the MXU-Setup (150I+27). Star ltt2415 and bd28d4211 would be prefered to link the data to former observations. ToO Information --------------- this is not a ToO programme Pre-Imaging Information ----------------------- No pre-imaging required. OBs are based on pre-images done with FORS2. OB Information ============== List of Science OBs with Associated Finding Charts -------------------------------------------------- Total Number of Submitted Science OBs: 16 Total Number of Submitted Finding Charts: 2 Setup A: -------- sciMXU FDF-A-1 = 68.A-0014A.001.ps sciMXU FDF-A-2 = 68.A-0014A.001.ps sciMXU FDF-A-3 = 68.A-0014A.001.ps sciMXU FDF-A-4 = 68.A-0014A.001.ps sciMXU FDF-A-5 = 68.A-0014A.001.ps Setup B: -------- sciMXU FDF-B-1 = 68.A-0014A.002.ps sciMXU FDF-B-2 = 68.A-0014A.002.ps sciMXU FDF-B-3 = 68.A-0014A.002.ps sciMXU FDF-B-4 = 68.A-0014A.002.ps sciMXU FDF-B-5 = 68.A-0014A.002.ps The eight OBs for each setup are identical (to allow flexible scheduling, see above) List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 16 Setup A: -------- calMXU FDF-A-1 calMXU FDF-A-2 calMXU FDF-A-3 calMXU FDF-A-4 calMXU FDF-A-5 Setup B: -------- calMXU FDF-B-1 calMXU FDF-B-2 calMXU FDF-B-3 calMXU FDF-B-4 calMXU FDF-B-5 The eight OBs for each setup are identical (in case the science Obs are done during different nights) OB Compliance Checks ==================== Y = Yes, N = No, NA = Not Applicable Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages [Y]? Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [Y] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [Y]? Did you submit the mandatory calibration OBs for each FORS MOS mask setup [Y]? Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages [NA]? If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars [NA]? [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page [NA]? [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA]? If you answered "NO" to any of these questions, please revise your OBs *before* submission.