README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 274.D-5047(A) Principal Investigator Name: P.G. Jonker Principal Investigator E-mail Address: peterj@sron.nl Principal Investigator Telephone Number: +31 30 253 8577 Principal Investigator Postal Address: Sorbonnelaan 2, 3584 CA, Utrecht, The Netherlands Instrument: FORS2 OPC Priority Class:A OPC Approved Total Execution Time:16 hr Estimated Total Execution Time (including overheads):15:54:05 README File Submission Date:08-03-2005 Programme Description ===================== Phase resolved spectroscopy of the counterpart of CirX-1. General Overview ---------------- At most one OB to be executed per night! Approved Waiver Request Summary ------------------------------- We are aware that the OB called CirX-1_PERIASTRON is longer than 1 hour, in case the seeing deteriorates significantly this OB does not have to be repeated. This 5 hour long observation was mentioned explicitly in the DDT proposal. Critical Observing Condition Constraints ---------------------------------------- Seeing better than 0.8" Time Critical Aspects --------------------- The OB called CirX-1_PERIASTRON should be executed on March 8, March 25, April 10, April 27, May 13, May 30, or June 21!! March 8 or March 25 is preferable! Special Calibration Information ------------------------------- ToO Information --------------- Pre-Imaging Requirements ------------------------ Source of preimaging: OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) CirX-1 CirX-1-0 CirX-1-1 CirX-1-2 CirX-1-3 CirX-1-4 CirX-1-5 CirX-1-6 CirX-1-7 CirX-1-8 CirX-1-9 CirX-1-10 CirX-1-11 CirX-1-12 CirX-1-13 CirX-1_PERIASTRON Total Number of Submitted Science OBs:16 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs:0 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [Y/N/NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [Y/N/NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [Y/N/NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [Y/N/NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [Y/N/NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [Y/N/NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.