README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 274.D-5025(A) Principal Investigator Name: Elena Mason Principal Investigator E-mail Address: emason@eso.org Principal Investigator Telephone Number: +2 436 0049 Principal Investigator Postal Address: ESO-Vitacura Instrument: FORS1 OPC Priority Class: DDT OPC Approved Total Execution Time: 7.1 hr Estimated Total Execution Time (including overheads): 7:05:33 README File Submission Date: Programme Description ===================== General Overview ---------------- The program consists in a monitor of the evolution of a recent classical nova through observations in (circular) linear spectropolarimetry mode. It is important to try to execute the observations at the trigger to a best effort, though the most critical part (the maximum) has been lost already. The attached finding chart is a DSS image with no nova. According to the coordinate in the IAUC we expect the nova to be within the red circle in the finding chart, or at the worst, close to it. It should be easily identifiable, however, at the time of the first activation. The OB name have a sequence number (1 to 8) followed by the exposure time in sec (i.e. 4x40 to 4 x1800, where 4 is the number of exposures in the OB). These exposures have been roughly evaluated assuming an average CN decline. There may be need to adjust those exposure times at the moment of the trigger, this will be specified in the activation mail. PLEASE execute the OB in the proper order in any case. The acquisition is in filter Halpha+83 or in R_BESS. Should the Halpha filter be not available change to R_BESS and decrease the exposure, if necessary. **************************************************************************** ********* NEW!!!! ********** **************************************************************************** NOTE: The OB Field_B574Pup is a PMOS observation of the filed in the direction of the nova. The purpose i to determine the polarization of nearby filed stars. Each slitlet should contain a target star visible at the acquisition and the through slit with just a 0.25 sec exposure. Standard calibration should follow the OB execution. If possible the polarimetric standard Vela or NGC2024 are preferred. ***************************************************************************** Approved Waiver Request Summary ------------------------------- Critical Observing Condition Constraints ---------------------------------------- Time Critical Aspects --------------------- Observe at the trigger e/o whenever specified in the email. Special Calibration Information ------------------------------- Please do not forget to observe a standard star at twilight. ToO Information --------------- It is a ToO with follow up character. In order to monitor properly the spectropolarimetric evolution of the nova each trigger should be not postponed too much (i.e. by more than 5-6 days or so). Pre-Imaging Requirements ------------------------ Source of preimaging: NA OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Total Number of Submitted Science OBs: 9 ToO_V574Pup_1_4x40.obx ToO_V574Pup_2_4x70.obx ToO_V574Pup_3_4x110.obx ToO_V574Pup_4_4x285.obx ToO_V574Pup_5_4x480.obx ToO_V574Pup_6_4x715.obx ToO_V574Pup_7_4x715.obx ToO_V574Pup_8_4x1800.obx Field_V574Pup.obx List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs:0 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y/N/NA] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y/N/NA] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y/N/NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y/N/NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [Y/N/NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [Y/N/NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [Y/N/NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [Y/N/NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [Y/N/NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [Y/N/NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.