README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 274.D-5011 Principal Investigator Name: Stefano Bagnulo Principal Investigator E-mail Address: sbagnulo@eso.org Principal Investigator Telephone Number: 00 56 2 4588729 (home) Principal Investigator Postal Address: ESO Chile, Vitacura Instrument: UVES OPC Priority Class: A OPC Approved Total Execution Time: 4h Estimated Total Execution Time (including overheads): 4h 01m README File Submission Date: Programme Description ===================== General Overview ---------------- This is a spectroscopic time series of a bright star. We have submitted 2 OBs. Each OB is composed of 88 exposures lasting 50 seconds, and the total duration of each OB is 2h. This program is time critical, in the sense that there are preferred dates for the observations. Approved Waiver Request Summary ------------------------------- We have been granted a waiver (274.D-5011.A01) to use "ultra-fast" (625 kHz) readout mode in service mode. We have been granted a waiver (274.D-5011.A02) to execute OBs longer that 1 hour. We are aware that Paranal SCIOPs guarrantees execution of the OB within user defined constraints only during the first hour. Critical Observing Condition Constraints ---------------------------------------- Time Critical Aspects --------------------- We would strongly prefer to have the 2 OBs executed *during two consecutive nights*, and during special nights, i.e.: 2004-11-11/12 and 2004-11-12/13 or 2004-11-12/13 and 2004-11-13/14 or 2004-11-24/25 and 2004-11-25/26 or 2004-11-25/26 and 2004-11-26/27 If the first OB is executed during night 2004-11-13/14, then please try to execute next in one of the nights 2004-11-24/25, 2004-11-25/26, (i.e., in this situation we override the "2 consecutive nights" rule) In any case, this program should be completed before December 5, as UVES observations should be done in parallel with the observations of the MOST satellite. Special Calibration Information ------------------------------- We use a 625 kHz setting, so please take daytime calibrations accordingly. ToO Information --------------- This is not a ToO Pre-Imaging Requirements ------------------------ None Source of preimaging: NA OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) HD 24712 A HD 24712 B Total Number of Submitted Science OBs: 2 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y/N/NA] Y Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y/N/NA] Y If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y/N/NA] NA Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y/N/NA] NA [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] Y [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [Y/N/NA] NA [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA] NA [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] NA [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [Y/N/NA] NA [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [Y/N/NA] NA [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [Y/N/NA] NA [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [Y/N/NA] NA [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [Y/N/NA] NA If you answered "NO" to any of these questions, please revise your OBs *before* submission.