README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 274.C-5032(A) Principal Investigator Name: Christoph Leinert Principal Investigator E-mail Address: leinert@mpia-hd.mpg.de Principal Investigator Telephone Number: +49 6221 528 264 Principal Investigator Postal Address: Max-Planck-Institute for Astronomy / Koenigstuhl 17 / D-69117 Heidelberg / Germany Instrument: MIDI OPC Priority Class: A OPC Approved Total Execution Time: 5.0 Estimated Total Execution Time (including overheads): 5.0 README File Submission Date: 22-12-2004 Programme Description ===================== General Overview ---------------- This is a repetition of MIDI observations of the young stars RY Tau, Z CMa, Haro 6-10 (both components) and FU Ori. The observations were originally done in the night of November 4/5 2004. Feasibility of the observations therefore can be taken granted. The time used for these observations in November (including a 24 minute attempt to lock on SVS 13) was 3:42 to 9:20 or slightly longer than 5 hours. Priority (but not proposed sequence of observations) is 1. Haro 6-10 (highest) 2. Z CMa and RY Tau (high) 3. FU Ori (lower) This means that in case of serious problems with execution time the observation of FU Ori could be cancelled. Z CMa and RY Tau should be observed on the baseline UT2/UT3 to obtain the wanted position angle on the sky (see "Time Critical Aspects"). For Haro 6-10 and FU Ori this baseline is not essential. If the total 5h cannot reasonably be found on UT2/UT3, doing the observation of Haro 6-10 and FU Ori the following night on UT3/UT4 is equally good and perhaps even preferable. Two calibrators are proposed, both used with good results previously: HD 25604 (**NOT** HD25605 !) which is up at dusk already, and HD 37160 for the rest of the observations. HD 37160 is important because it is a spectrophotometric calibrator. All objects can and have been used as their own guide star for the MACAO system under normal MACAO operation. Should still be problems with the MACAO unit on UT2, still the visually brighter targets should work well, but it may not be possible to close the loop on Haro 6-10. Under these difficult conditions, Haro 6-10 has to be handled as "infrared source" (discussed in "Critical Observing Condition Constraints"). As an informative guideline, the following sequence of observations would fulfil the needs of our observing programme on UT2/UT3: 2:00 h ST calibrator HD 25604 (already higher than 30 degrees) 2:30 h ST object RY Tau (good position angle and > 30 deg) 3:00 h ST object Z CMa (at best position angles and >30 deg) 3:30 h ST calibrator HD 37160 (spectrophotometric, > 40 deg) 4:00 h ST objects Haro 6-10 (components separately, = 40 deg) 5:00 h ST calibrator HD 37160 (spectrophotometric, > 50 deg) 5:30 h ST object FU Ori (> 40 deg) 6:00 h ST - buffer - (always some small problems occur) 6:30 h ST calibrator HD 37160 (spectrophotometric, > 50 deg) Approved Waiver Request Summary ------------------------------- none Critical Observing Condition Constraints ---------------------------------------- First case: If Haro 6-10 can be observed with MACAO, the calibrator measurement on HD 37160 following it has also to be observed with MACAO. This will be a completely normal measurement except for the necessary movement between the components. Acquisition probably will bring the visually visible southern component into the MIDI field (the other component is very faint visually). The northern component, normally 50% or so brighter around 10 micron, is 1.2 arcsec off almost due north. (north direction on the chip can already be known from a quick reduction of one of the earlier measurements with Christian Hummel's package, chosing "Heidelberg"). For offsetting, the command OFFSGP (which does not interrupt the difficult enough to close MACAO loop) is recommended, available on the operator console for the delay line, I remember. Going 0.5'' north both components should be visible in the MIDI field of view. Seeing both components in both beams is necessary if one wants to be sure that light from the **same** component is used for interferometry. After one component has been measured, the other one should be centered **without** new preset and using the command OFFSGP to go close enough to the component position for sucessful automatic centering. Do **not** use delta offsets on the telescope console, MACAO will quickly pull back to the component you were observing before (we did this not so obvious error in June). And, please, keep a log allowing to relate the two observations each to the correct one of the two components. Second case: The MACAO loop cannot be closed on Haro 6-10 for both telescopes. Then Haro 6-10 has to be centered as infrared source without MACAO. The seeing conditions should be reasonably good, say <= 0.8 arcsec. Care has to be taken, as said for the first case, that one is on the same components for both beams. Offsetting is now easier, however, one can use the telescope consoles for the 1.2'' in delta between the southern and the northern component. Please, keep also in this case a log allowing to relate the two measurements each to the correct one of the two components. The calibrator measurement on HD37160 following the measurements on Haro 6-10 has to be done in the same way as the measurement on Haro 6-10, i.e. in this case without use of MACAO. Time Critical Aspects --------------------- In order to get the best position angle for the measurement on the sky and to have the object at elevation higher than 30 degrees, the following ranges of sidereal time should be used for the observations: - RY Tau (ST 2:30 - 6:00 for a position angle of about 50 degrees) - Z CMa (ST 3h - 4h for a position angle 0-20 deg. at >30 deg. elevation). These two are more important constraints, but should not lead to cancelling of the observations if violated to some extent. For the remaining objects the request is mainly an elevation > 30 degrees: - Haro 6-10 (ST 2:30 - 6:30) - FU Ori (ST 2:30 -9:00) The latter two are weak constraints. Special Calibration Information ------------------------------- In general standard MIDI calibration. But one exception: Please do the calibrator measurement on HD 37160 which follows the measurement on Haro 6-10, in the same mode like the measurement on Haro 6-10, i.e. with or without MACAO, depending on what was done for Haro 6-10 (see "Critical Observing Condition Constraints). Name: HD 37160 Coordinates: 05 36 54.39, +09 17 26.2 (J2000.0) V magnitude: 4.1 mag N magnitude: 6.5 Jy ~ 1.9 mag Spectral Type: K0IIIb Uniform Disk (UD) diameter at N band with error: 2.02 +- 0.02 mas Source of diameter estimate: MIDI calibrator list (B. Stecklum et al.) Name: HD 25604 Coordinates: 04 04 41.70+22 04 55.0 (J2000.0) V magnitude: 4.4 mag N magnitude: 5.1 Jy ~ 2.2 mag Spectral Type: K0III Uniform Disk (UD) diameter at N band with error: 1.88 +- 0.05 mas Source of diameter estimate: MIDI calibrator list (B. Stecklum et al.) ToO Information --------------- none Pre-Imaging Requirements ------------------------ Source of preimaging: none OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Total Number of Submitted Science OBs: 5 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 5 SCI_RYTau <-> CAL_HD25604 SCI_ZCMa <-> CAL_HD37160Z SCI_Haro610 <-> CAL_HD37160H SCI_Haro610NOAO <-> CAL_HD37160NOAO SCI_FUOri <-> CAL_HD37160F OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y/N/NA] Y Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y/N/NA] Y If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y/N/NA] NA Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y/N/NA] NA [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] NA [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [Y/N/NA] NA [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA] NA [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] NA [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [Y/N/NA] NA [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [Y/N/NA] NA [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [Y/N/NA] NA [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [Y/N/NA] Y [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [Y/N/NA] Y If you answered "NO" to any of these questions, please revise your OBs *before* submission.