README Template 73.1 (please do not delete the README Template Version line!) ESO Programme ID: 273.D-5043(A) Principal Investigator Name: Martin Asplund Principal Investigator E-mail Address: martin@mso.anu.edu.au Principal Investigator Telephone Number: +61 2 6125 8041 Principal Investigator Postal Address: Mt Stromlo Observatory / Cotter Rd / Weston ACT 2611 / Australia Instrument: UVES OPC Priority Class: A OPC Approved Total Execution Time: 5.5 Estimated Total Execution Time (including overheads): 5.5 README File Submission Date: 24 August 2004 Programme Description ===================== General Overview ---------------- This is a simple spectroscopic program of two stars but with extremely stringent requirements for the quality of the observed spectrum. Approved Waiver Request Summary ------------------------------- We have requested that we use the 600nm standard UVES setting without the iodine cell. A waiver request was submitted Aug. 15 and approved Aug. 18. Critical Observing Condition Constraints ---------------------------------------- Good seeing <1.4" Time Critical Aspects --------------------- The earlier these DDT observations are done the better, in particular since one of the objects (HD140283) is only observable early in the evening during the next few weeks. Special Calibration Information ------------------------------- We request that 8 FF and 3 ThAr exposures with appropriate exposure times, i.e. well exposed and not too close to saturation (especially for the FF), are taken in the morning for each of the night(s) with science observations to ensure nearly the same UVEs pressure and temperature. This is important in order to realise the highest possible quality in the reduced spectra as the analysis require extra-ordinary high S/N of the reduced data. The normal number of BIAS and DARK frames for the UVES pipeline data reduction is sufficient. Also, it is important that the FF and ThAr frames are taken without the IS but with a slit as long as the output of the slicer. ToO Information --------------- This is not a ToO programme. Pre-Imaging Requirements ------------------------ No pre-imaging is required for this programme. Source of preimaging: Not applicable OB Information ============== List of Science OBs ------------------- Total Number of Submitted Science OBs: 6 HD140283_Red600nm_im3_1 LP815_Red600nm_im3_1 LP815_Red600nm_im3_2 LP815_Red600nm_im3_3 LP815_Red600nm_im3_4 LP815_Red600nm_im3_5 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? Y Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? Y If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? N/A Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? N/A [FORS only] Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [NA] [FORS only] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? Y [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [Y] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.