README Template 73.1 (please do not delete the README Template Version line!) ESO Programme ID: Principal Investigator Name: Henk Spruit Principal Investigator E-mail Address: henk@mpa-garching.mpg.de Principal Investigator Telephone Number: 089 30000 2220 Principal Investigator Postal Address: MPI f Astro, Postfach 1317, 85741 Garching Instrument: FORSII OPC Priority Class: A OPC Approved Total Execution Time: 7h Spent so far: 2h Estimated Total Execution Time these OBs (including overheads): 4.5h README File Submission Date: 7/5/2004 Programme Description ===================== General Overview ---------------- The main goal is to get make optimal use of the time when XTE is observing simultaneously. The time variability of the target probably depends on wavelength, hence the switching of filters in some of the observations. Since most of the science will come out of the cross-correlation of the signal with the X-rays, calibrations are less critical. For photometric noise as low as possible, a good comparison star on the slit is needed. Instrument rotator setting as been chosen accordingly. A wide slit has been chosen to minimize risks of loss in poor seeing. Approved Waiver Request Summary ------------------------------- Obs > 1hr approved because XTE orbits are longer Critical Observing Condition Constraints ---------------------------------------- Since simultaneity with XTE is overriding for the observations, constraints on sky conditions have been set low. These observations can be done as long as some light gets through the clouds. Time Critical Aspects --------------------- In `time intervals' I have set acceptable times (UT, including date!) for START of the observations (including 10 min setup as suggested by the execution calculator). The main concern here is not to loose XTE time, i.e. the science exposures have to include all XTE time. I've set the science exposures for a total of the XTE time plus about 20min at the beginning and end. The XTE observing times are (they are also given in the `user comment' line of the OBs): 11/5 (UT) 09:15-09:49 12/5 (UT) 08:52-09:26 13/5 (UT) 08:29-09:02 14/5 (UT) 08:06-08:38 Special Calibration Information none ------------------------------- ToO Information N/A --------------- Pre-Imaging Requirements N/A ------------------------ Source of preimaging: OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) 339XTE2 339XTE3 339XTE4 339XTE5 Total Number of Submitted Science OBs: 4 List of Calibration OBs with Associated Science OBs N/A --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [N] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [Y/N/NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [Y/N/NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [Y/N/NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [Y/N/NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [Y/N/NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.