README Template 68.1 ESO Programme ID: 268.D-5738(A) Principal Investigator: Glenn Wahlgren Contact Person Name: Glenn Wahlgren & Swetlana Hubrig Contact Person E-mail Address: glenn.wahlgren@astro.lu.se shubrig@eso.org Contact Person Telephone Number: 46-46-222 1582 (Wahlgren) 56-2-463 3102 (Hubrig) Instrument: UVES OPC Priority Class: C OPC Approved Total Execution Time: 0.6 hour Estimated Total Execution Time (including overheads): 0.6 hour README File Submission Date: 2 November 2001 Programme Description ===================== General Overview ---------------- The bright star HD 358 (V = 2.1 mag) will be observed during twilight hours on four separate evenings using the UVES instrument. For each of the four visits observations will be made with both the dic-2 and dic-1 setups. Full active optics is not to be used for target acquisition. Waiver Request Summary ---------------------- Critical Observing Condition Constraints ---------------------------------------- Spectrum can become saturated. In such a case the OB should be repeated with a shorter exposure time, but acquiring a S/N > 300. Exposure times are very short, perhaps 6 sec, and a difference of 1 sec can make a big difference in whether an exposure becomes saturated. Time Critical Aspects --------------------- The program is now comprised of 8 OBs. Only two blocks (one each for observations with dic-2 and dic-1) are to be executed during any night. Only one visit to the target is to be conducted during any night. The observations are prioritized such that the dic-2 exposure is priority 1 and dic-1 has a priority of 2 for each evening. If during the dic-1 exposure the observation must be stopped, fails or is not executed, then the dic-1 observation OB is not to be repeated prior to the dic-2 OB on the next available evening. The star shows a spectrum variability with a period of 2.4 days. Observations can be executed on any night but not at the same phase (+/- 0.1 phase). The nightly variation is 0.4 in phase. Special Calibration Information ------------------------------- No special calibrations. ToO Information --------------- This is not a ToO program. Pre-Imaging Information ----------------------- No pre-imaging required. OB Information ============== List of Science OBs with Associated Finding Charts -------------------------------------------------- Total Number of Submitted Science OBs: 8 Total Number of Submitted Finding Charts: 0 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== Y = Yes, N = No, NA = Not Applicable Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages [Y]? Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [NA] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [NA]? Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages [Y]? If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars [NA]? [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page [NA]? [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA]? If you answered "NO" to any of these questions, please revise your OBs *before* submission. Destination Address for Data Products ===================================== raw data products to be sent to Swetlana Hubrig (shubrig@eso.org), ESO Santiago and pipeline products to be sent to Glenn Wahlgren (glenn.wahlgren@astro.lu.se), Astronomy Dept., Lund University, Box 43, SE-22100, Lund, Sweden *************************************** DO NOT WRITE BELOW THESELINES!!!!!!!!! ***************************************