README Template 68.1 ESO Programme ID: 268.C-5772 Principal Investigator: Hatzes Contact Person Name: Artie Hatzes Contact Person E-mail Address: artie@tls-tautenburg.de Contact Person Telephone Number: +49-36427-863-51 Instrument: UVES DDTC Priority Class: B DDTC Approved Total Execution Time: 10.0 Estimated Total Execution Time (including overheads): 10.0 README File Submission Date: 28 March 2002 Programme Description ===================== General Overview ---------------- This is a simple spectroscopic observation with UVES using the UVES_red_obs_std standard setting. Waiver Request Summary ---------------------- Critical Observing Condition Constraints ---------------------------------------- This project can be carried out under reasonably poor seeing conditions. For all observations the UVES_red_obs_std_600 setting is used. The 23 OBs for object X are called X-A, X-B X-C....X-H, -pure, etc. Time Critical Aspects --------------------- We are trying to get good phase coverage to derive an orbit. Each target observed with the iodine cell should be taken on separate nights so as to ensure that all these observations are not at the same orbital phase. Random sampling is best (although it would be a appreciated if you could check to be sure you are not observing the star at the same phase). Note that the pure spectrum of the star (without iodine) can be taken prior to or just after a spectrum taken with the cell. This will save acquisition time. Target OGLE-TR-10: Period = 3.1 d. Spectra taken through the cell can be taken on three consecutive nights. The next 3 spectra (D-F) after at least another week gap, and finally the last two after another week or more gap, or randomly. Target OGLE-TR-40: Period = 3.4 d. Spectra taken through the cell can be taken on consecutive nights, i.e. one per night, or randomly. Target OGLE-TR-9: Period = 3.27 d. Spectra taken through the cell can be taken on consecutive nights or randomly. Special Calibration Information ------------------------------- Just standard calibration is needed (ThAr, Flat, Bias, Iodine spectrum (i.e. flat lamp taken through the iodine cell). The observations are done in 2x2 binning so *all* calibrations should be done with the same binning. ToO Information --------------- This is not a ToO programme. Pre-Imaging Information ----------------------- We are using image slicer #1. Slit-viewer should be used to put the object into the image slicer. This is a crowded field so the finding charts will definitely be needed. OB Information ============== List of Science OBs with Associated Finding Charts -------------------------------------------------- Total Number of Submitted Science OBs: 23 Total Number of Submitted Finding Charts: 3 OB: Finding_Chart: TR-9-iodine-A = 268.C-5772A.001.ps TR-9-iodine-B = 268.C-5772A.001.ps TR-9-iodine-C = 268.C-5772A.001.ps TR-9-iodine-D = 268.C-5772A.001.ps TR-9-pure = 268.C-5772A.001.ps TR-10-iodine-A = 268.C-5772A.002.ps TR-10-iodine-B = 268.C-5772A.002.ps TR-10-iodine-C = 268.C-5772A.002.ps TR-10-iodine-D = 268.C-5772A.002.ps TR-10-iodine-E = 268.C-5772A.002.ps TR-10-iodine-F = 268.C-5772A.002.ps TR-10-iodine-G = 268.C-5772A.002.ps TR-10-iodine-H = 268.C-5772A.002.ps TR-10-pure = 268.C-5772A.002.ps TR-40-iodine-A = 268.C-5772A.003.ps TR-40-iodine-B = 268.C-5772A.003.ps TR-40-iodine-C = 268.C-5772A.003.ps TR-40-iodine-D = 268.C-5772A.003.ps TR-40-iodine-E = 268.C-5772A.003.ps TR-40-iodine-F = 268.C-5772A.003.ps TR-40-iodine-G = 268.C-5772A.003.ps TR-40-iodine-H = 268.C-5772A.003.ps TR-40-pure = 268.C-5772A.003.ps List of Calibration OBs with Associated Science OBs --------------------------------------------------- Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== Y = Yes, N = No, NA = Not Applicable Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages [Y]? Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [NA] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [NA]? Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages [Y]? If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars [NA]? [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page [NA]? [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA]? If you answered "NO" to any of these questions, please revise your OBs *before* submission. Destination Address for Data Products ===================================== Artie Hatzes Thueringer Landessternwarte Tautenburg D-07778 Tautenburg GERMANY *************************************** DO NOT WRITE BELOW THESE LINES!!!!!!!!! ***************************************