README Template 69.1 ESO Programme ID: 169.A-0595(A) Principal Investigator Name: Hans Boehringer Principal Investigator E-mail Address: hxb@mpe.mpg.de Principal Investigator Telephone Number: =49 89 30000 3347 Instrument: FORS2 OPC Priority Class: A OPC Approved Total Execution Time: 2.0 Estimated Total Execution Time (including overheads): 2.01 README File Submission Date: Programme Description ===================== Three observing runs have been allocated to the program: ProgID RunID M Cat TEL INS Hours/Nights ---------- ------------- - --- --- ------ ------------------------------ 6905950 169.A-0595(A) s A UT4 FORS2 2.0 6905950 169.A-0595(B) s A UT4 FORS2 10.0 6905950 169.A-0595(C) s A UT1 FORS1 30.0 ------------------------------------------------------------------------ (A) Preimaging and photometry - later use for XMU spectroscopy (run B) (B) XMU spectroscopy of 8 fields (3 objects) - the observation details will be submitted after the preimaging (C) separate README-file describes these observations This README file describes the observing run (A). There are 11 exposures of 8 fields R 3 fields B in 3 objects In two of the fields occulting bars are used. General Overview ---------------- List of observations and total exposure time as calculated in the P2PP-report Programme Id Id | OB Name Exposure Time Execution Time -------------- -------------------------------- ------------- -------------- 169.A-0595(A) PRER0454-1808bB 00:05:00.000 00:11:00.000 169.A-0595(A) PRER0454-1808aB 00:05:00.000 00:11:00.000 169.A-0595(A) PRER0454-1808cB 00:05:00.000 00:11:00.000 169.A-0595(A) PRER2139-2228bR 00:05:00.000 00:11:00.000 169.A-0595(A) PRER2139-2228aR 00:05:00.000 00:11:00.000 169.A-0595(A) PRER0953-1558cR 00:05:00.000 00:11:00.000 169.A-0595(A) PRER0953-1558bR 00:05:00.000 00:11:00.000 169.A-0595(A) PRER0953-1558aR 00:05:00.000 00:11:00.000 169.A-0595(A) PRER0454-1808cR 00:05:00.000 00:11:00.000 169.A-0595(A) PRER0454-1808bR 00:05:00.000 00:11:00.000 169.A-0595(A) PRER0454-1808aR 00:05:00.000 00:11:00.000 ------------- -------------- Totals 00:55:00.000 02:01:00.000 --------------------------------------------------------------------------------------------------- Waiver Request Summary ---------------------- none Critical Observing Condition Constraints ---------------------------------------- none Time Critical Aspects --------------------- none Special Calibration Information ------------------------------- none ToO Information --------------- none Pre-Imaging Information ----------------------- This is a preimaging run ! observations should be taken early enough that the XMU spectroscopy can follow in P69 (about 2 month after imaging) OB Information ============== List of Science OBs with Associated Finding Charts -------------------------------------------------- Total Number of Submitted Science OBs: 11 Total Number of Submitted Finding Charts: 8 OBs finding charts special comments --------------------------------------------------------- PRER0454-1808aR 169.A-0595A.001.ps PreImaging PRER0454-1808aB 169.A-0595A.001.ps PreImaging PRER0454-1808bR 169.A-0595A.002.ps PreImaging PRER0454-1808bB 169.A-0595A.002.ps PreImaging PRER0454-1808cR 169.A-0595A.003.ps PreImaging PRER0454-1808cB 169.A-0595A.003.ps PreImaging PRER0953-1558aR 169.A-0595A.004.ps PreImaging PRER0953-1558bR 169.A-0595A.005.ps PreImaging PRER0953-1558cR 169.A-0595A.006.ps PreImaging PRER2139-2228aR 169.A-0595A.007.ps PreImaging PRER2139-2228bR 169.A-0595A.008.ps PreImaging List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== Y = Yes, N = No, NA = Not Applicable Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages [Y]? Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [Y] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [NA]? Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages [NA]? If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars [NA]? [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page [NA]? [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA]? If you answered "NO" to any of these questions, please revise your OBs *before* submission. Destination Address for Data Products ===================================== Dr. Hans Boehringer Max-Planck-Institut fuer extraterr. Physik Giessenbachstr. 1 D-85741 Garching