README Template 73.1 (please do not delete the README Template Version line!) ESO Programme ID: 168.A-0485(C) Principal Investigator Name: Catherine Cesarsky Principal Investigator E-mail Address: ccesarsk@eso.org Principal Investigator Telephone Number: +49-89-3200-6227 Principal Investigator Postal Address: European Southern Observatory / Karl-Schwarzschild-Str. 2 / D-85748 Garching b. Muenchen / Germany Instrument: VIMOS OPC Priority Class: A OPC Approved Total Execution Time: 40.0 Estimated Total Execution Time (including overheads): 40.0 README File Submission Date: 09 July 2004 Programme Description ===================== General Overview ---------------- This is the VIMOS U-band imaging of the Chandra Deep Field South as part of the public GOODS survey (http://www.eso.org/science/goods/). Approved Waiver Request Summary ------------------------------- - Critical Observing Condition Constraints ---------------------------------------- Whenever possible execute the OBs in dark time since we are after very faint objects. Note that there is a priority given to each U-band field (ranging from 1 to 8). Please always finish a given pointing (5 OBs) before you start on another pointing. Time Critical Aspects --------------------- - Special Calibration Information ------------------------------- In total we have 8 different pointings, each 5 OBs slightly (up to +-10") dithered. Only one of the 5 OBs per pointing needs to be carried out in photometric conditions. The photometric OBs are indicated by a preceding "ZERO" in the OB name. If possible carry out these OBs at low airmass - the constraint is set to airmass <=1.2 We require the observation of two special calibration OBs (STD_Feige110, STD_Feige110_off). This spectrophotometric std star (Feige110) will be used to derive the zero point of the non-standard VIMOS U-band filter. This star has a U-band magnitude of ~11.0 (Spectral type: DOp) and the observations are therefore close to the saturation limit. So please do *not* turn on the active mirror control and observe in bad seeing conditions if possible. Please do carry out your standard U-band photometric calibration in any case. ToO Information --------------- - Pre-Imaging Requirements ------------------------ - OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Total Number of Submitted Science OBs: 42 special calibration OBs: STD_Feige110 : spectrophotometric std star STD_Feige110_off : spectrophotometric std star offset by ~10" The following OBs are listed in order of priority; first one is most important one VIMOS_GOODS_U_01a,b,c,d,e : field 01; 5 OBs VIMOS_GOODS_U_02a,b,c,d,e : field 02; 5 OBs VIMOS_GOODS_U_03a,b,c,d,e : field 03; 5 OBs VIMOS_GOODS_U_04a,b,c,d,e : field 04; 5 OBs VIMOS_GOODS_U_05a,b,c,d,e : field 05; 5 OBs VIMOS_GOODS_U_06a,b,c,d,e : field 06; 5 OBs VIMOS_GOODS_U_07a,b,c,d,e : field 07; 5 OBs VIMOS_GOODS_U_08a,b,c,d,e : field 08; 5 OBs List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [N] [FORS only] Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [NA] [FORS only] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [Y] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [Y] If you answered "NO" to any of these questions, please revise your OBs *before* submission.