README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 074.D-0710(A) Principal Investigator Name: Gerald Bourban Principal Investigator E-mail Address: gerald.bourban@obs.unige.ch Principal Investigator Telephone Number: +41 22 755 26 11 Principal Investigator Postal Address: Observatoire de Geneve / ch. des Maillettes 51 / CH-1290 Sauvergny / Switzerland Instrument: FEROS OPC Priority Class: B OPC Approved Total Execution Time: 7.6 Estimated Total Execution Time (including overheads): 7.56 README File Submission Date: 25 August 2004 Programme Description ===================== General Overview ---------------- This is a spectroscopic follow-up program consisting of one spectra carried out each night during 17 nights. These measurements will allow us to build the radial velocity curve of the target, i.e the microquasar candidate 1RXSJ162848.1-415241. Moreover, the spectra will be used for the spectral type of the optical component of this system. Approved Waiver Request Summary ------------------------------- No Critical Observing Condition Constraints ---------------------------------------- No. The values provided in the "Constraint Set" in the OBs are to be considered as references. Time Critical Aspects --------------------- In order to get a good phase coverage, the whole program (the 17 measurements, one per night) should be splitted into three different sequences (1, 2 and 3). By considering the observability of the target, the following time windows result: Obs. Blocks Time Window Sequ 1: FEROS_seq1_objcal_1200-(0 to 8) : 2004-10-01 to 2004-10-12 Sequ 2: FEROS_seq2_objcal_1200-(0 to 3) : 2005-03-01 to 2005-03-05 Sequ 3: FEROS_seq3_objcal_1200-(0 to 3) : 2005-03-25 to 2005-03-31 During the Sequence 1 the target is visible at the begining of the night while during the Sequences 2 and 3 it is visible at the end of the night. Special Calibration Information ------------------------------- No. The daily calibrations described in the FEROS Calibration Plan are suitable for our program. ToO Information --------------- This is not a ToO program. Pre-Imaging Requirements ------------------------ No pre-imaging is required for this program. Source of preimaging: Not applicable OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Total Number of Submitted Science OBs: 17 FEROS_seq1_objcal_1200-0 FEROS_seq1_objcal_1200-1 FEROS_seq1_objcal_1200-2 FEROS_seq1_objcal_1200-3 FEROS_seq1_objcal_1200-4 FEROS_seq1_objcal_1200-5 FEROS_seq1_objcal_1200-6 FEROS_seq1_objcal_1200-7 FEROS_seq1_objcal_1200-8 FEROS_seq2_objcal_1200-0 FEROS_seq2_objcal_1200-1 FEROS_seq2_objcal_1200-2 FEROS_seq2_objcal_1200-3 FEROS_seq3_objcal_1200-0 FEROS_seq2_objcal_1200-1 FEROS_seq2_objcal_1200-2 FEROS_seq2_objcal_1200-3 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [N] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.