README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 074.D-0625(A) Principal Investigator Name: Darach Watson Principal Investigator E-mail Address: darach@astro.ku.dk Principal Investigator Telephone Number: +45 35325994 Principal Investigator Postal Address: Astronomical Observatory / University of Copenhagen / Juliane Maries Vej 30 / DK-2100 Copenhagen OE / Denmark Instrument: FORS1 OPC Priority Class: A OPC Approved Total Execution Time: 3.0 hours Estimated Total Execution Time (including overheads): 3.0 hours README File Submission Date: 25 August 2004 Programme Description ===================== General Overview ---------------- ToO spectroscopy of a GRB afterglow/host galaxy to find the redshift consisting of 3 hours of (300V) spectroscopy -- final choice of grism depends on the predicted redshift of the galaxy: see proposal box 12. Approved Waiver Request Summary ------------------------------- None Critical Observing Condition Constraints ---------------------------------------- None Time Critical Aspects --------------------- ToO Special Calibration Information ------------------------------- ToO Information --------------- Target still sufficiently bright (R~23): redshift predicted from X-ray lines. Pre-Imaging Requirements ------------------------ None Source of preimaging: N/A OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Total Number of Submitted Science OBs: 9 TOO 3x800LSS +2off - 600I TOO 3x800LSS 5off - 600I TOO 3x800LSS -2off - 600I TOO 3x800LSS +2off - 300V-GG435 TOO 3x800LSS 5off - 300V-GG435 TOO 3x800LSS -2off - 300V-GG435 TOO 3x800LSS -2off - 300V-none TOO 3x800LSS 5off - 300V-none TOO 3x800LSS +2off - 300V-none List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [NA] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.