README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 074.D-0601(A) Principal Investigator Name: Tijl Verhoelst Principal Investigator E-mail Address: tijl@ster.kuleuven.ac.be Principal Investigator Telephone Number: +3216327039 Principal Investigator Postal Address: Celestijnenlaan 200B, B-3001 Leuven BELGIUM Instrument: MIDI OPC Priority Class: A OPC Approved Total Execution Time: 6h Estimated Total Execution Time (including overheads): 6h README File Submission Date: 26/08/04 Programme Description ===================== General Overview ---------------- This program consists of the observation of 2 science targets (TX Psc and R Scl), each with an appropriate calibrator. The goal is to probe the visibility curve at 3 different locations within the first lobe, by observing at different projected baselines. Since these stars are variabele (R Scl to an extreme degree), it is crucial that all 3 observations of each star happen within one or a few consecutive nights. Expected visibility dependence on wavelength is very large! Approved Waiver Request Summary ------------------------------- none Critical Observing Condition Constraints ---------------------------------------- none Time Critical Aspects --------------------- Please do all 3 observations of each star within one or a few consecutive nights. Within the night, please do not hesitate to observe close to the 40 deg elevation limit: we would like one of the 3 points per star to correspond to a small projected baseline. The R Scl observations are to be done in the second MIDI service run, i.e. between december 27th and january 2nd, since we plan simultaneous UKIRT spectroscopy (and UKIRT is not available the other 2 periods). Special Calibration Information ------------------------------- none ToO Information --------------- NA Pre-Imaging Requirements ------------------------ NA Source of preimaging:none OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) SCI_R_Scl_1 SCI_R_Scl_2 SCI_R_Scl_3 SCI_TX_Psc_1 SCI_TX_Psc_2 SCI_TX_Psc_3 Total Number of Submitted Science OBs: 6 List of Calibration OBs with Associated Science OBs --------------------------------------------------- CAL_hd219615_1 (SCI_TX_Psc_1) CAL_hd219615_2 (SCI_TX_Psc_2) CAL_hd219615_3 (SCI_TX_Psc_3) CAL_hd12524_1 (SCI_R_Scl_1) CAL_hd12524_2 (SCI_R_Scl_2) CAL_hd12524_3 (SCI_R_Scl_3) Total Number of Submitted Calibration OBs: 6 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [Y] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.