README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 074.D-0573 Principal Investigator Name: Bringfried Stecklum Principal Investigator E-mail Address: stecklum@tls-tautenburg.de Principal Investigator Telephone Number: +49-36427-863-54 Principal Investigator Postal Address: TLS Tautenburg, Sternwarte 5, D-07778 Instrument: UVES OPC Priority Class: B OPC Approved Total Execution Time: 4 Estimated Total Execution Time (including overheads): 06:46:48.000 README File Submission Date: 25 August 2004 Programme Description ===================== General Overview ---------------- The proposal aims at resolving disks of Be stars by means of spectroastrometry. For this purpose, spectra of the 3 targets shall be taken at 12 slit position angles in steps of 30 degrees. The spatial extent and orientation of the disks will be derived from the displacement of the centroid positions across the H_alpha line with respect to the continuum. Since the stars are bright (V=3...4), very short integration times have to be applied. The target acquisition has to be done using the pre-slit filter #2 mentioned in the UVES OB template manual for which, however, no check box is available in p2pp-2.8. The total time demand is dominated by overheads. It seems reasonable that the total execution time computed by p2pp is not representative and larger than the time which will be actually needed (see OB information for detailed estimate). Approved Waiver Request Summary ------------------------------- none Critical Observing Condition Constraints ---------------------------------------- none Time Critical Aspects --------------------- none Special Calibration Information ------------------------------- none ToO Information --------------- not applicable Pre-Imaging Requirements ------------------------ none Source of preimaging: OB Information ============== Since the orientation of the slit cannot be changed with the science OB it has to be done in the acquisition OB. Therefore 12 OBs per source are provided. For this reason p2pp includes the time for telescope pointing, slit centering, and UVES setup for _each_ position angle in the computation of the total execution time. Due to the very small DIT it seems reasonable, however, that at least a few if not all spectra for one target can be taken subsequentially. In this case only one telescope pointing is needed. This would yield the following revised execution time per target: pointing + UVES setup + 12*(slit centering+3*(DIT + read-out time)) which amounts to about 55 minutes (or 34 minutes if the slit centering has to be done only once). Thus the total execution time for the provided OBs is likely to be about 1.5 to 3 hours and therefore less than the 4 hours granted by the OPC. The field of view of the finding charts amounts to 5' x 5' since due to the brightness of the stars and their saturated images in the DSS2, the default size for UVES (1' x 1') would render them useless. List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Total Number of Submitted Science OBs: 36 HD_62623-000 HD_62623-030 HD_62623-060 HD_62623-090 HD_62623-120 HD_62623-150 HD_62623-180 HD_62623-210 HD_62623-240 HD_62623-270 HD_62623-300 HD_62623-330 beta_CMi-000 beta_CMi-030 beta_CMi-060 beta_CMi-090 beta_CMi-120 beta_CMi-150 beta_CMi-180 beta_CMi-210 beta_CMi-240 beta_CMi-270 beta_CMi-300 beta_CMi-330 zeta_Tau-000 zeta_Tau-030 zeta_Tau-060 zeta_Tau-090 zeta_Tau-120 zeta_Tau-150 zeta_Tau-180 zeta_Tau-210 zeta_Tau-240 zeta_Tau-270 zeta_Tau-300 zeta_Tau-330 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y/N/NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.