README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 074.D-0544(A)/SM/MIDI Principal Investigator Name: Griet Van de Steene Principal Investigator E-mail Address: gsteene@oma.be Principal Investigator Telephone Number: +32 494 33 21 08 Principal Investigator Postal Address: R.O.B., Ringlaan 3, 1180 Brussels, Belgium Instrument: MIDI OPC Priority Class: A OPC Approved Total Execution Time: 7 h Estimated Total Execution Time (including overheads): 7h README File Submission Date: 06 October 2004 Programme Description ===================== General Overview ----------------- MIDI observations of the disk in Hen2-90. There is only one object to be observed on 3 different baselines. U2-U4: 3 visibilities (V1,V2,V3) with prism. 1 OB submitted per visibility. U3-U4: 3 visibilities (V1,V2,V3) with prism. 1 OB submitted per visibility. U2-U3: 1 visibility (V1) with grism. 1 OB submitted. Priority: 4, so that it is executed after the other OB's. Of course, based on the collected information, we think that Hen2-90, is bright enough, but if not so, please obtain this visibility with the prism. Apparently Hen2-90 is bright enough to be used as a GUIDE STAR, however it might be extended. If it turns out unsuitable, the following stars are indicated on the finding charts and could be used as well: GSC1: 13:09:31.16 -61:20:10.4 J2000.0 GSC2: 13:09:29.56 -61:19:48.6 J2000.0 GSC3: 13:09:37.72 -61:20:19.7 J2000.0 The FINDING CHART 074.D-544.001.jpg is a 5'x5' DSS-2 finding chart. The file 074.D-0544.002.jpg is the high resolution optical HST image of the object to be observed, and 074.D-0544.003.jpg is DSS-2 infrared finding chart. Approved Waiver Request Summary ------------------------------- Critical Observing Condition Constraints ---------------------------------------- For a limited number of interferometric observations it is important to cover the UV plane as well as possible. Therefore it is very important that, at least per baseline, each visibility is obtained at different hour angles. Time Critical Aspects --------------------- For a limited number of interferometric observations it is important to cover the UV plane as well as possible. The object is visible from ST 10 h until about ST 16 h. I have indicated ST ranges per OB in which the OB can be started, ONLY to avoid that visibilities are obtained at the same hour angle. Hence the object is observable beyond these ST ranges and it is not critical that the observations get finished within these ST ranges. Unfortunately, there is no ideal way to indicate the UV-plane coverage without unnecessarily overconstraining the time that the observations get scheduled. If you take this into account automatically, the indicated ST ranges could be extended. Special Calibration Information ------------------------------- As we have only one object, we chose only one calibrator. A calibrator was chosen using CalVin. It is HD122451, diameter 0.96", N=1.52 mag, B1III, at 14:03:49.40 -60:22:22.90 J2000.0. ToO Information --------------- NA Pre-Imaging Requirements ------------------------ Source of preimaging: OB Information ============== Total Number of Submitted Science OBs: 14, of which 7 science OB's and 7 calibration OB's. List of Science OBs ------------------- There is only one object to be observed on 3 baselines. There is one science OB per visibility point. SCI_Hen2-90_U2U4_V1, SCI_Hen2-90_U2U4_V2, SCI_Hen2-90_U2U4_V3; SCI_Hen2-90_U3U4_V1, SCI_Hen2-90_U3U4_V2, SCI_Hen2-90_U3U4_V3; SCI_Hen2-90_U2U3 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 7 We only have one object to be observed on 3 baselines, hence there is only one calibrator. CAL_U2U3_HD122451 for the visibility with the grism on the U2U3 baseline, i.e. science OB SCI_Hen2-90_U2U3 3 x CAL_U3U4_HD122451 for the 3 visibilities with the prism on the U3U4 baseline, i.e. science OB's SCI_Hen2-90_U3U4_V1,SCI_Hen2-90_U3U4_V2,SCI_Hen2-90_U3U4_V3 3 x CAL_U2U4_HD122451 for the 3 visibilities with the prism on the U2U4 baseline, i.e. science OB's SCI_Hen2-90_U2U4_V1,SCI_Hen2-90_U2U4_V2,SCI_Hen2-90_U2U4_V3 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? Y Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? Y If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? Y Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? N [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? Y [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? NA If you answered "NO" to any of these questions, please revise your OBs *before* submission.