README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 074.D-04319(A) Principal Investigator Name: Christian Knigge Principal Investigator E-mail Address: christian@astro.soton.ac.uk Principal Investigator Telephone Number: +44-(0)2380-593955 Principal Investigator Postal Address: School of Physics & Astronomy, University of Southampton Southampton SO17 1BJ United Kindom Instrument: VLT/FLAMES OPC Priority Class: B OPC Approved Total Execution Time: 15 hrs Estimated Total Execution Time (including overheads): 8.0 hrs README File Submission Date: Sep 2, 2004 Programme Description ===================== General Overview ---------------- This is a VLT/FLAMES/GIRAFFE/ARGUS program to obtain orbital phase-resolved and spatially resolved spectroscopy of the recurrent nova T Pyx. The main goal is to measure orbital phase-linked radial velocities across its 1.83 hour period. In order to sample a full binary orbit at a time, we require observing sequences of two hours on target. We have therefore prepared OBs which consist of 28 exposures spanning a full binary orbit. This strategy was reached after repeated consultation with the USG staff and represents the most efficient use of VLT time. Approved Waiver Request Summary ------------------------------- Given the above strategy, our OBs last 2 hours each and exceed the nominal 1 hour limit. A waiver request was approved for the reasons detailed above. Indeed these OBs were created after specific guidelines provided by the USG and Paranal staff. Critical Observing Condition Constraints ---------------------------------------- N/A Time Critical Aspects --------------------- N/A Special Calibration Information ------------------------------- N/A ToO Information --------------- N/A Pre-Imaging Requirements ------------------------ N/A Source of preimaging: N/A OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Total Number of Submitted Science OBs: 4 TPyxARGUS-1 TPyxARGUS-2 TPyxARGUS-3 TPyxARGUS-4 Please note that these are identical OBs. Each uses (the same) FPOSS configuration that has been validated for hour angles +/- 4 hours. The guide star magnitude is R=11.8, and the four fiducial stars range from R=12.4 to R=13.1 Each OB consists of 28 short exposures (180s each), and we anticipate to achieve a S/N~20 per exposure. List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y] [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [Y] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.