README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 074.D-0369(B) Principal Investigator Name: F.R.Ferraro Principal Investigator E-mail Address:francesco.ferraro3@unibo.it Principal Investigator Telephone Number:+390512095774 Principal Investigator Postal Address: Astronomy Dept. - Bologna University - Via Ranzani, 1 - 40127 BOLOGNA (ITALY) Instrument: FORS1 OPC Priority Class: A OPC Approved Total Execution Time: 8 h Estimated Total Execution Time (including overheads): 7h 59m README File Submission Date: 29 July 2004 Programme Description ===================== This is a programme aimed to understand the origin of the anomalous populations detected in the Color Magnitude Diagramme of the globular cluster Omega Centauri (NGC5139). In particular, this part of the programme [074.D-0369(B)] is devoted to image (in two broad-band filters, B and R, respectively) a mosaic of 8 FORS1 (Standard resolution) fields in the halo of the cluster. The final aim of this part of the project is to study the radial distribution of the blue Main Sequence detected with the Hubble Space Telescope. In order to optimize the execution of the OBs we requested (and obtained 074.D-0369B.01.WAV) to use the two broad-band filters in each single OB. In this way we have an OB for each selected field of the mosaic. Each OB will execute two exposures in each filter: 2 exposures in B (each 1100 sec long) and 2 in R (each 395 sec long). The total execution time of each OB is always less than 1 hour. In the case of field 7 and 8 (OBs: NGC5139-7 and NGC5139-8) we used the occulting bars of the MOS unit in order to avoid strong saturation from bright stars in the field. Then, the two OBs has been prepared with FIMS. General Overview ---------------- This is a simple imaging programme consisting of 8 independent OBs. Approved Waiver Request Summary ------------------------------- 074.D-0369B.01.WAV: we have requested that we use more than one filter per OB. This request was submitted on 20 July 2004 and approved on 21 July 2004. Critical Observing Condition Constraints ---------------------------------------- The most critical observing condition is the seeing which is required to be better than 0.6 arcsec. All the OBs are requested to be executed under CLEAR conditions (photometric conditions are NOT required). Time Critical Aspects --------------------- No time critical aspects Special Calibration Information ------------------------------- No special calibration. ToO Information --------------- This is not a ToO programme. Pre-Imaging Requirements ------------------------ This is not a Pre-imaging programme. Source of preimaging: OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Total Number of Submitted Science OBs: 8 NGC5139-1 NGC5139-2 NGC5139-3 NGC5139-4 NGC5139-5 NGC5139-6 NGC5139-7 NGC5139-8 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.