README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 074.D-0305(A) Principal Investigator Name: Enzo Brocato Principal Investigator E-mail Address: brocato@te.astro.it Principal Investigator Telephone Number: +39 0861 210490 Principal Investigator Postal Address: INAF- Osservaorio Astronomico Teramo Via M. Maggini snc / I-64100 TERAMO / ITALY Instrument: FLAMES OPC Priority Class: C OPC Approved Total Execution Time: 22.5 Estimated Total Execution Time (including overheads): 21:45 README File Submission Date: 28 September 2004 Programme Description ===================== General Overview ---------------- We plan to secure high resolution spectroscopy of a selected sample of stars of the LMC cluster NGC 1866 with the aim of deriving a statistically reliable metallicity and detailed elemental abundances of the NGC 1866 stars experiencing different evolutionary phases. Together with the already secured HST and VLT data, these spectra will make NGC 1866 the best studied sample of intermediate mass stars ( ~ 4 Mo) and the best benchmark to probe - at the same time - stellar evolution and stellar pulsation theories. As immediate goals, we expect: i) to derive a robust (Cepheids + MS fitting) determination of the distance of the LMC; ii) to quantify the efficiency of the mixing due to rotation in stars with masses of the order of 4 Mo; iii) to understand why different masses are derived by pulsation and by stellar evolution theories for Cepheid stars; iv) to map the relative abundances (including s-elements) along the evolution of stars of intermediate mass from the MS to the AGB phase. Approved Waiver Request Summary ------------------------------- Critical Observing Condition Constraints ---------------------------------------- none Time Critical Aspects --------------------- none Special Calibration Information ------------------------------- none ToO Information --------------- This is not a ToO programme. Pre-Imaging Requirements ------------------------ No pre-imaging is required for this programme. Source of preimaging: OB Information ============== RA(J2000) DEC(J2000) VLT Guide Star V = 12.2 5 12 50.49 -65 32 50.10 Fiducial stars (FACB) V = 13.02 5 13 27.68 -65 25 15.80 Fiducial stars (FACB) V = 13.78 5 14 15.55 -65 26 59.10 Fiducial stars (FACB) V = 12.26 5 13 07.37 -65 27 17.30 The hour angle range in which each field configuration field is valid is +/- 5.0 h (this is valid for all the OBs) The targeted S/N per pixel is of the order of 25 for a single exposure Giraffe std setup HR11 572.8 The targeted S/N per pixel is of the order of 10 for a single exposure UVES std setup Red 580 The targeted S/N per pixel is of the order of 35 for a single exposure Giraffe std setup LR02 427.2 List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Total Number of Submitted Science OBs: 17 Fibers positions remain the same for all the OBs NGC1866_A-0 NGC1866_A-1 NGC1866_A-2 NGC1866_A-3 NGC1866_B-0 NGC1866_B-1 NGC1866_B-2 NGC1866_B-3 NGC1866_C-0 NGC1866_C-1 NGC1866_C-2 NGC1866_D-0 NGC1866_D-1 NGC1866_E-0 NGC1866_E-1 NGC1866_F-0 NGC1866_F-1 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [NA] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [/NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [/NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.