README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: Principal Investigator Name: Markus Wittkowski Principal Investigator E-mail Address: mwittkow@eso.org Principal Investigator Telephone Number: +49-89-3200-6769 Principal Investigator Postal Address: ESO Garching Instrument: MIDI OPC Priority Class: B OPC Approved Total Execution Time: 3h Estimated Total Execution Time (including overheads): 3h README File Submission Date: Sep 01, 2004 Programme Description ===================== General Overview ---------------- These are MIDI/PRISM observations of the bright Mira variable star S Ori at two epochs. We have also obtained time for concurrent VLBA observations. We would like to match the VLBA and VLTI epochs as close as possible through further communication. For VLTI, we observe 2 epochs, each epoch including one OB for each of the three different baselines. The 2 epochs shall be separated by 1-3 months. This run A is for epoch 1. Run B is for epoch 2. The goal of this program is to determine to parameters of the dust envelope of S Ori, with respect to the location of the SiO maser emission, and to monitor variations of these structures as a funtion of stellar variability phase. Approved Waiver Request Summary ------------------------------- none Critical Observing Condition Constraints ---------------------------------------- none Time Critical Aspects --------------------- The three OBs (using three different baselines) of this run should preferably be executed as close in time as possible. These observations should be executed during the first half of P74 to allow a second epoch (run B) in the second half of P74. Special Calibration Information ------------------------------- none ToO Information --------------- not a ToO Pre-Imaging Requirements ------------------------ none Source of preimaging: OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) see below Total Number of Submitted Science OBs: 3 List of Calibration OBs with Associated Science OBs --------------------------------------------------- SCI_sori_epoch1-b1 / CAL_hd50778-epoch1-b1 for UT2-3 SCI_sori_epoch1-b2 / CAL_hd50778-epoch1-b2 for UT3-4 SCI_sori_epoch1-b3 / CAL_hd50778-epoch1-b3 for UT2-4 Total Number of Submitted Calibration OBs: OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? Y Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? Y If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? NA Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? Y [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? NA [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? NA [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? NA [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? NA [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? NA [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? NA [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? NA [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? Y [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? NA If you answered "NO" to any of these questions, please revise your OBs *before* submission.