README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 074.C-0789(B) Principal Investigator Name: Serge Correia Principal Investigator E-mail Address: scorreia@aip.de Principal Investigator Telephone Number: +49 (0)331 7499 334 Principal Investigator Postal Address: Astrophysikalisches Institut Potsdam, An der Sternwarte 16, D-14482 Potsdam, Germany Instrument: ISAAC OPC Priority Class: C OPC Approved Total Execution Time: 01:30:00 Estimated Total Execution Time (including overheads): 01:32:15 README File Submission Date: 06 August 2004 Programme Description ===================== General Overview ---------------- This is a spectroscopic programme with the goal to obtain K-band low resolution (R=600, SWS1-LR, 2.2um central wavelength, 0.8" slit) spectra of the single components of well separated pairs (> 2") within triple/quadruple pre-main sequence stars. The procedure is to obtain spectra of pairs simultaneously by placing the 0.8" slit along their orientations. The Finding Charts show the position of the slit overlaid on Brackett gamma 2.17um narrow-band images of the systems as obtained by our survey with NACO in P70. Larger field-of-view (typically 4'x4') finding charts in K-band (from 2MASS) are also available including ISAAC FOV. The observing spectroscopic procedure adopted is standard : 1 ABBA cycle with a nod throw of 15" and a jitter box width of 3". The DITs are 60s and 90s, depending of the brightness of the pair. Note that the target acquisition make use of a narrow-band filter as requested on the instrument specific Phase 2 Web page, because of the brightness of the targets (K>8). The final goal is to derive spectral types of the previously unresolved stars of these systems, and to obtain informations about their accretion properties in order to indentify the proportion of actively accreting (CTTS) vs not accreting (WTTS) components. A change of instrument mode has been approved by ESO. Briefly, K&L imaging and medium resolution spectroscopy has been replaced by low resolution spectroscopy only, as described above. The reasons are mainly due to an underestimate of the overheads needed for such observations into the proposal. Approved Waiver Request Summary ------------------------------- - Critical Observing Condition Constraints ---------------------------------------- - Time Critical Aspects --------------------- - Special Calibration Information ------------------------------- - ToO Information --------------- - Pre-Imaging Requirements ------------------------ Source of preimaging: OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Total Number of Submitted Science OBs: 5 Sz41 AC - Ks spectro K=8.0 Sz41 AB - Ks spectro K=8.0 Sz30 AC - Ks spectro K=9.6 LkHa 336 AC - Ks spectro K=9.2 LkHa 336 AB - Ks spectro K=9.2 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [Y] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.