README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 074.C-0718A Principal Investigator Name: Paul Kalas Principal Investigator E-mail Address: kalas@astron.berkeley.edu Principal Investigator Telephone Number: +1 (510) 642-8285 Principal Investigator Postal Address: Astronomy Dept. 601 Campbell Hall University of California Berkeley, CA 94720 USA Instrument: NACO OPC Priority Class:B OPC Approved Total Execution Time: 9.3 Estimated Total Execution Time (including overheads): 9.3 README File Submission Date: October 15, 2004 Programme Description ===================== General Overview ---------------- The goal is to obtain high contrast observations of the environment of a bright star AU Mic. AU Mic has a very sharp (edge-on) circumstellar disk at position angle 124 degrees. Science observations are best acquired when telescope diffraction spikes are not at this angle. PSF star observations can be obtained at any time. If different rotator tracking modes are available, then PSF subtraction from star to star is most successful if the rotator keeps the pupil fixed and the sky is allowed to rotate. Coronagraphic images are obtained with the 0.7" opaque occulting spot, and each OB has a sequence of "short" exposures. The goal of the short exposures is to obtain images that are NOT SATURATED and LINEAR at the edge of the occulting spot. The DIT value will depend on seeing and AO performance. The telescope operator may shorten or lengthen the short exposure DIT values to approach but not exceed the saturation level of CONICA. All OB's also have "long" exposure sequences that may be in the NONLINEAR regime of the detector and no greater than the accepted 2x saturation limit. Three OB's are dedicated to H-band dual-channel polarimetric imaging using the Wollaston. A PSF reference star is added for the H-band dual-channel polarimetric observations. To avoid detector saturation in this part of the project, we use the S13 camera and the neutral density filter. AU Mic and the two PSF stars serve as their own wavefront reference source. NOTE that the PSF reference stars are used for PSF subtraction and not for deconvolution. Therefore the PSF reference stars are also occulted with the coronagraph. Approved Waiver Request Summary ------------------------------- Critical Observing Condition Constraints ---------------------------------------- Time Critical Aspects --------------------- In general, PSF subtraction is most successful if the science target (AU Mic) and the two PSF stars are observed during the same night for a given filter. For example, rather than obtain J, H, K images of AU Mic on one night, and JHK images of the PSF stars on the second night, it is better to obtain K-band images of AU Mic and at least one PSF star during the same night. J-band imaging and H-band imaging should be similarly grouped together. Special Calibration Information ------------------------------- ToO Information --------------- Pre-Imaging Requirements ------------------------ Source of preimaging: OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Total Number of Submitted Science OBs: 05 01 AU Mic - J 02 AU Mic - H 03 AU Mic - K 04 AU Mic Pol - H 05 AU Mic Pol - H (repeat of 04) List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 06 01 psf-HD191849-J Science OB = AU Mic - J 02 psf-HD191849-H Science OB = AU Mic - H 03 psf-HD191849-K Science OB = AU Mic - K 04 psf-HD191849-POL Science OB = AU Mic POL - H 05 psf-HD202560-H Science OB = AU Mic - H 06 psf-HD202560-K Science OB = AU Mic - K OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.