README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 074.C-0327(A) Principal Investigator Name: Ruslan Yudin For any question/problem please contact: N. Ageorges Principal Investigator E-mail Address: nageorge@eso.org (ruslan61@gao.spb.ru) Principal Investigator Telephone Number: +56-2-463-3119 Principal Investigator Postal Address: ESO - Alonso de Cordova 3107 - Vitacura - Santiago - Chile Instrument: NACO OPC Priority Class: A OPC Approved Total Execution Time: 10.0 Estimated Total Execution Time (including overheads): 10:00:02 README File Submission Date: Programme Description ===================== General Overview ---------------- This program aims at detecting circumstellar disk around Herbig Ae/Be stars. It is a simple polarimetric imaging program. However since the objects are extended, we are using the wire-grids instead of the Wollaston prisms. As a consequence photometric conditions are an ABSOLUTE requirement. The DITs have been determined for each object in order to guarante the peak flux to be within the linearity range of the detector. It should thus not be a problem for the polarimetry but please *check carefully for non-linearity (saturation)* and feel free to change DIT/NDIT accordingly. Thank you. For 2 objects (Vy Mon & Z CMa) we are using the Vis WFS. For the others, the IR WFS has been selected. For the case that V380 Ori & Nx Pup do saturate the IR WFS, we prepared a second reference star, the same object (= the science target) but with the Vis WFS. Approved Waiver Request Summary ------------------------------- On August 18th, our waiver request have been accepted. Note that the first part of the waiver is pointless as of Sept. 23rd (the OBs have been modifed). REQUEST > > From: nageorge@eso.org > > Subject: 074.C-0327(A) > > > > Dear all, > > > > This is a multiple waiver request for proposal 074.C-0327(A). > > > > 1/ We ask for permission to have 2 OBs longer than 01:05. > > According to the p2pp execution time, these OBs will have a duration of > > 01:05:52 & 01:05:32 respectively. > > > > 2/ We ask for the permission to gain 2 seconds of time compared to the > > total amount allocated. > > Indeed, still according to the p2pp (version 2.8) execution time report, > > all our OBs will add to a total > > of 10hours 2 seconds, whereby we have been allocated only 10hours. > > > > 3/ It is fundamental for us that the standard star be observed the same > > night as the science object. > > We thus ask for the permission to add this extra constraint to the > > observations. In the worst case, the > > execution of the science OB and standard will add to 01:45:25. We are > > aware that this is a non classical > > request and accept to see the standard star taken under poor/degraded > > performance and outside > > user's contraint as long as it is observed immediately after a > > successfully executed science OB. > > In the worst case, the standard can also be taken in opened loop (if > > needed). It will not need to be re-executed > > (of course providing the corresponding science target was successfully > > observed just before). > > > > Thank you to give full consideration to these requests. > > > > Bests regards, > > > > Nancy Ageorges / Ruslan Yudin > > ANSWER > Subject: Re: URGENT: 074.C-0327A.01.WAV [Request for Review] > Date: Wed, 18 Aug 2004 11:06:58 +0200 > From: Fernando Comeron > > Dear Nancy, > > We are please to let you know that the waiver request is approved. The > third point is accepted under the conditions that you describe: this is, > once the science > observation is completed, the standard will be observed independent of > fulfilment of the constraints and the observation will be deemed > successfully completed in any case: neither the science OB nor the > standard OB will be repeated if the standard > observation is out of specs. Of course, the standard OB will be started > only if the science OB has been completed within constraints. > > Best regards, > > Fernando Critical Observing Condition Constraints ---------------------------------------- The targets are bright and could almost be done under any seeing or airmass. The only CRUCIAL point for us is to have the OBs executed under PHOTOMETRIC conditions. Time Critical Aspects --------------------- The standard has to be observed just after the prime science target, e.g. Std_HkOri has to be observed just after HkOri. (WAIVER granted - see above) If a science OB has been executed fully within constraints, the standard must be observed just after, even if this means violating airmass constraint &/or image quality (the AO is actually not necessary for the standard, which can - if necessary - be taken in open loop). Special Calibration Information ------------------------------- The acquisition of the standard after a science OB. (See time critical aspects & waiver) ToO Information --------------- N/A Pre-Imaging Requirements ------------------------ None OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Total Number of Submitted Science OBs: 6 OB Name - Observing priority - Magnitude of brightest object in field HkOri.obx - priority 1 - K=7.3, H=8.3 V380Ori.obx - priority 1 - K=5.9, H=6.9 MWC137.obx - priority 2 - K=6.6, H=7.8 VyMon.obx - priority 2 - K=5.5, H=6.7 ZCMa.obx - priority 1 - K=3.8, H=5.2 NxPup.obx - priority 1 - K=6.1, H=7.3 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 6 OB Name - Observing priority - Magnitude of brightest object in field std_HkOri.obx - priority 1 - K=8.8, H=9.1 std_V380Ori.obx - priority 1 - K=9.5, H=9.5 std_MWC137.obx - priority 2 - K=8.8, H=9.1 std_VyMon.obx - priority 2 - K=8.8, H=9.1 std_ZCMa.obx - priority 1 - K=4.8, H=5.0 std_NxPup.obx - priority 1 - K=12.4, H=12.5 These are polarimetric standards. The star used as standard for HkOri, MWC137 & VyMon is the same, but needs to be observed in relation with each prime science target; this is why we submit 3 independant OBs. OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y] [FORS only] Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [NA] [FORS only] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.