README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 074.C-0144(C) Principal Investigator Name: Mugrauer Principal Investigator E-mail Address: markus@astro.uni-jena.de Principal Investigator Telephone Number: +49-(0)3641-947518 Principal Investigator Postal Address: Schillergäßchen 2-3 07745 Jena Instrument: FORS-2 OPC Priority Class: B OPC Approved Total Execution Time: 2h Estimated Total Execution Time (including overheads): 1h53min README File Submission Date:07/08/2004 Programme Description ===================== General Overview ---------------- This a spectroscopy program using FORS-2 GRIS300I+23 with order separation filter OG590+32. A faint companion close to a much brighter primary. The position angle and distance of the companion are shown in the finding charts. The bright primaries are used as acquisition objects, hence acquisition with a OII+44 narrow band filter. A offset relative to the primary is applied to move the companion on the slit, that must be checked by the observer. 11 spectra with 200s integration time should be taken. After each integration an offset along the slit is applied (for background subtraction). Approved Waiver Request Summary ------------------------------- Critical Observing Condition Constraints ---------------------------------------- Seeing ~1 arcsec; clear sky; airmass < 1.5 or (1.8) see OBs; Time Critical Aspects --------------------- Special Calibration Information ------------------------------- Only standard calibration (flats, wavecal and standard star) ToO Information --------------- No Pre-Imaging Requirements ------------------------ Source of preimaging: No OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) GJ3021_spec HD27442_spec Total Number of Submitted Science OBs: 2 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y/N/NA] Y Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y/N/NA] Y If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y/N/NA] NA Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y/N/NA] NA [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [Y/N/NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [Y/N/NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [Y/N/NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [Y/N/NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [Y/N/NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [Y/N/NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.