README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 074.C-0111(B) Principal Investigator Name: Juan M. Alcala' Principal Investigator E-mail Address: jmae@na.astro.it Principal Investigator Telephone Number: +39-081-5575-479 Principal Investigator Postal Address: INAF- Osservatorio Astronomico di Capodimonte / Via Moiariello 16 / I-80131 Napoli / Italy Instrument: VIMOS OPC Priority Class: B OPC Approved Total Execution Time: 18 Estimated Total Execution Time (including overheads): 17.92 README File Submission Date: 29 October 2004 Programme Description ===================== General Overview ---------------- This is a VIMOS program consisting of six fields in two star forming regions (four in L1616 and two in Dolize 25). Approved Waiver Request Summary ------------------------------- No waiver request was submitted Critical Observing Condition Constraints ---------------------------------------- Because of atmospheric dispersion problems the observations shloud be carried out at +/-2 hrs from meridian. This leads to the constrain on the airmass to be less than 1.2 Time Critical Aspects --------------------- no critical aspects other than the observability of the fields from October 2002 to March 2003. Special Calibration Information ------------------------------- no special calibration informations are submitted ToO Information --------------- This is not a ToO programme. Pre-Imaging Requirements ------------------------ This is not a pre-imaging program. OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Total Number of Submitted Science OBs: 30 L1616_n1_HR_M1_1 L1616_n1_HR_M1_2 L1616_n1_MR_M1 L1616_n1_MR_M2 L1616_n1_MR_M3 L1616_n2_HR_M1_1 L1616_n2_HR_M1_2 L1616_n2_MR_M1 L1616_n2_MR_M2 L1616_n2_MR_M3 L1616_n3_HR_M1_1 L1616_n3_HR_M1_2 L1616_n3_MR_M1 L1616_n3_MR_M2 L1616_n3_MR_M3 L1616_s1_HR_M1_1 L1616_s1_HR_M1_2 L1616_s1_MR_M1 L1616_s1_MR_M2 L1616_s1_MR_M3 Dol25_1_HR_M1 Dol25_1_HR_M2 Dol25_1_MR_M1 Dol25_1_MR_M2 Dol25_1_MR_M3 Dol25_2_HR_M1 Dol25_2_HR_M2 Dol25_2_MR_M1 Dol25_2_MR_M2 Dol25_2_MR_M3 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [Y/N/NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [Y/N/NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [Y] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [Y] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [Y/N/NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [Y/N/NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.