README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 074.0066 (B) Principal Investigator Name: Artie Hatzes Principal Investigator E-mail Address: artie@tls-tautenburg.de Principal Investigator Telephone Number: +49-36427-863-51 Principal Investigator Postal Address: Prof. Dr. Artie Hatzes Thueringer Landessternwarte Tautenburg Sternwarte 5 D-07778 Tautenburg Germany Instrument: UVES OPC Priority Class: B OPC Approved Total Execution Time: 10.00 Estimated Total Execution Time (including overheads): 10.00 README File Submission Date: Programme Description ===================== General Overview ---------------- These are spectroscopic observations with UVES using the UVES_red_obs_exp 600 standard setting and the iodine absorption cell. The cell is used for precise radial velocity measurements and is placed in the the light path during an observation. We only need a few template spectra (star without iodine). The naming convention for the OBs are "objectname_type" where objectname is the object, type is either "iodine" or "template". ******* IMPORTANT *************************************************** As part of the reduction procedure we need to deconvolve the instrumental profile from the template spectrum (spectrum of star without iodine). To do that requires an observation of a hot star (HR 948) taken through the cell (the standard iodine spectrum through the flat is insufficient for this). Thus, when you take a template spectrum you should also observe the hot star HR 948 once through the cell and once without (through the cell has the highest priority). **** If you do not take a template spectrum on a given night do not take a spectrum of the calibration hot star (HR 948), I repeat do not waste an OB observing on HR 948. That observation would be useless and an OB will be wasted!! **** Please note, that if several template spectra of different stars are taken on the same night, then only one series of HR 948 (through cell and without cell) is needed. If you can, try to take several template observations in the same night as this is more efficient and requires less OBs. Note that the first time a star is observed it makes sense to take a sequence with the cell and then one without (this will save acquisition time Since we have only 5 template stars I have included only 2 sets (iodine + no iodine) for HR 948. Approved Waiver Request Summary ------------------------------- Critical Observing Condition Constraints ---------------------------------------- Time Critical Aspects --------------------- Special Calibration Information ------------------------------- Just standard calibration is needed (ThAr, Flat, Bias, Iodine spectrum (i.e. flat lamp taken through the iodine cell). *** It is important that along with the other calibrations that an iodine spectrum is taken using the flat lamp. *** ToO Information --------------- Pre-Imaging Requirements ------------------------ We are using image slicer #3. Slit-viewer should be used to put the object into the image slicer. These are relatively bright stars in not-so-crowded fields, so the finder charts should not really be needed. Source of preimaging: OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Total Number of Submitted Science OBs: 32 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.