README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 074.C-0034(A) Principal Investigator Name: Thomas Stanke Principal Investigator E-mail Address: stanke@ifa.hawaii.edu Principal Investigator Telephone Number: +1 808 956 6664 Principal Investigator Postal Address: Institute for Astronomy, University of Hawaii, 2680 Woodlawn Drive, Honolulu, Hawaii 96822, USA Instrument: WFI OPC Priority Class: B OPC Approved Total Execution Time: 20.0 Estimated Total Execution Time (including overheads): 20 README File Submission Date: Programme Description ===================== General Overview ---------------- This is a search for Herbig-Haro Emission line nebulosities in Orion. It requires imaging through narrow band Halpha and SII filters as well as a medium-band continuum filter. First priority OBs are: Pos_D_SII, Pos_E_SII, Pos_F_SII, Pos_H_Ha, Pos_U_Ha, Pos_H_SII, and Pos_U_SII these positions have been started already in an earlier run. Generally, we suggest the follow this observing strategy: - During the first session take continuum images of a number (3-4) of survey fields - During the subsequent sessions, take Halpha images of these - Then, during the next sessions, take SII images of these - Then go to new fields, and start with continuum images, and so on... At the end of any session, please take a spectrophotometric standard exposure on LTT3864 through the filters that were used during the session. In addition, dome and sky-flats are needed. Approved Waiver Request Summary ------------------------------- Critical Observing Condition Constraints ---------------------------------------- Search for low surface brightness features --> dark time is very important! Future proper motion studies would benefit from good seeing. Time Critical Aspects --------------------- Special Calibration Information ------------------------------- Skyflats and domeflats have to be taken for the filters used during the repsective nights. Corresponding calibration OBs have been submitted (not all of which probably will have to be observed). Spectrophotometric standards: The data need not be taken under perfectly photometric conditions, but some brightness calibration would be useful: Please observe LTT3864, a spectrophotometric standard, with the filters used for the science frames) once after the night/session. The corresponding OBs are included. LTT 3864: V=12.17, SpT F (observable later in the night) ToO Information --------------- Pre-Imaging Requirements ------------------------ Source of preimaging: OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Total Number of Submitted Science OBs: 34 Pos_D_SII Pos_E_SII Pos_F_SII Pos_H_Ha Pos_H_SII Pos_K_c Pos_K_Ha Pos_K_SII Pos_M_c Pos_M_Ha Pos_M_SII Pos_N_c Pos_N_Ha Pos_N_SII Pos_P_c Pos_P_Ha Pos_P_SII Pos_R_c Pos_R_Ha Pos_R_SII Pos_S_c Pos_S_Ha Pos_S_SII Pos_U_Ha Pos_U_SII LTT3846cont LTT3846cont-0 LTT3846Ha LTT3846Ha-0 LTT3846Ha-1 LTT3846SII LTT3846SII-0 LTT3846SII-1 LTT3846SII-2 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 36 flat_dome_c (all *cont and *_c OBs) flat_dome_c-0 (all *cont and *_c OBs) flat_dome_c-1 (all *cont and *_c OBs) flat_dome_c-2 (all *cont and *_c OBs) flat_dome_c-3 (all *cont and *_c OBs) flat_dome_c-4 (all *cont and *_c OBs) flat_dome_Ha (all *Ha OBs) flat_dome_Ha-0 (all *Ha OBs) flat_dome_Ha-1 (all *Ha OBs) flat_dome_Ha-2 (all *Ha OBs) flat_dome_Ha-3 (all *Ha OBs) flat_dome_Ha-4 (all *Ha OBs) flat_dome_SII (all *Sii OBs) flat_dome_SII-0 (all *Sii OBs) flat_dome_SII-1 (all *Sii OBs) flat_dome_SII-2 (all *Sii OBs) flat_dome_SII-3 (all *Sii OBs) flat_dome_SII-4 (all *Sii OBs) flat_sky_c (all *cont and *_c OBs) flat_sky_c-0 (all *cont and *_c OBs) flat_sky_c-1 (all *cont and *_c OBs) flat_sky_c-2 (all *cont and *_c OBs) flat_sky_c-3 (all *cont and *_c OBs) flat_sky_c-4 (all *cont and *_c OBs) flat_sky_Ha (all *Ha OBs) flat_sky_Ha-0 (all *Ha OBs) flat_sky_Ha-1 (all *Ha OBs) flat_sky_Ha-2 (all *Ha OBs) flat_sky_Ha-3 (all *Ha OBs) flat_sky_Ha-4 (all *Ha OBs) flat_sky_SII (all *Sii OBs) flat_sky_SII-0 (all *Sii OBs) flat_sky_SII-1 (all *Sii OBs) flat_sky_SII-2 (all *Sii OBs) flat_sky_SII-3 (all *Sii OBs) flat_sky_SII-4 (all *Sii OBs) OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y/N/NA] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y/N/NA] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y/N/NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y/N/NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [Y/N/NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [Y/N/NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [Y/N/NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [Y/N/NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [Y/N/NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [Y/N/NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.