README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 074.B-0602(A) Principal Investigator Name: Nadine Haering Principal Investigator E-mail Address: haering@mpia.de Principal Investigator Telephone Number: +49 6221 528 384 Principal Investigator Postal Address: Max-Planck Institut fuer Astronomie Koenigstuhl 17 69117 Heidelberg Germany Instrument: NACO OPC Priority Class: A OPC Approved Total Execution Time: 8 h Estimated Total Execution Time (including overheads): 8 h README File Submission Date: 25 August 2004 re-submission date: 27 September 2004 Programme Description ===================== General Overview ---------------- This is mainly a spectroscopy programme with an additional aqcuisition image in FeII narrow band. The photometric standard stars should be executed directly after the science OB with the same WFS setup (they are at the same time PSF reference - the PSF flag is set to true in the OB.) NGC5128_FeII_img-0 - CAL-PSF-S273-E_FeII-0 NGC5128_FeII_img-1 - CAL-PSF-S273-E_FeII-1 NGC5128_FeII_img-2 - will be cross calibrated For spectroscopy: The slit should be centred on the photometric centre of the galaxy for all position angles. The IR wavefront sensor has to be used for all OBs. In the last runs it has been shown that the WFS-mode 5-3 works best for this object. For all observation (H-band and NB_1.64) the K dicroic is used. Approved Waiver Request Summary ------------------------------- We were granted to take [FeII] imaging observations of CenA, although not requested in the original proposal. submitted: 6 September 2004 approved: 14 September 2004 Critical Observing Condition Constraints ---------------------------------------- The spectroscopy OBs should be executed under clear conditions. For a good and stable AO performance on this pretty difficult target seeing should be stable and < 0.8". Time Critical Aspects --------------------- No constraints. Special Calibration Information ------------------------------- For the photometric calibration of the images OBs photometric standards are submitted. They should be executed directly after the science OB with the same WFS setup (since they are used as PSF reference, too.) NGC5128_FeII_img-0 - CAL-PSF-S273-E_FeII-0 NGC5128_FeII_img-1 - CAL-PSF-S273-E_FeII-1 The third FeII imaging sequence (NGC5128_FeII_img-2) can be cross-calibrated. ToO Information --------------- This is not a ToO programme. Pre-Imaging Requirements ------------------------ No pre-imaging is required for this programme. Source of preimaging: Not applicable OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Total Number of Submitted Science OBs: magnitude of brightest object: NGC5128_FeII_img-2 Nucleus in H-band: 13.7 mag in K-band: 10.9 mag NGC5128_FeII_img-1 13.7 mag NGC5128_FeII_img-0 13.7 mag NGC5128_NUC_spec_H_-10deg 13.7 mag NGC5128_NUC_spec_H_-14deg 13.7 mag NGC5128_NUC_spec_H_109deg 13.7 mag NGC5128_NUC_spec_H_51deg 13.7 mag NGC5128_NUC_spec_H_83deg 13.7 mag List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 2 PSF-S273-E_H m_K = 10.849 spectral type: K0 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.