README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 074.B-0446 Principal Investigator Name: Edgardo Costa Principal Investigator E-mail Address: costa@das.uchile.cl Principal Investigator Telephone Number:56-2-2294002 Principal Investigator Postal Address: Dpto. de Astronomia, Universidad de Chile, Casilla 36-D, Santiago, Chile Instrument: FORS2 OPC Priority Class: A OPC Approved Total Execution Time: 11.1h Estimated Total Execution Time (including overheads): 11h README File Submission Date: 15.11.2004 Programme Description ===================== General Overview ---------------- This is a spectroscopic programme to obtain low-resolution spectra of RGB stars in different regions of the SMC, in the CaII Triplet region (8500A). Observations of 7 calibrating clusters are also requested. After adquiring and placing the stars on the slits, we obtain two exposures by shifting along the slit to improve sky substraction. Approved Waiver Request Summary ------------------------------- The addition of a number of calibrating clusters has been aproved (USG-11728) Critical Observing Condition Constraints ---------------------------------------- This programme does not need special conditions, thin clouds and bright time are acceptable. Time Critical Aspects --------------------- Special Calibration Information ------------------------------- No special calibrations are necessary ToO Information --------------- Pre-Imaging Requirements ------------------------ Source of preimaging: 074.B-0446(A) and ESO archive OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for 0each OB) Total Number of Submitted Science OBs: 20 SMC0033-7028 SMC0035-7201 SMC0036-7226 SMC0037-7218 SMC0047-7530 SMC0049-7544 SMC0052-7646 SMC0057-7353 SMC0100-7457 SMC0102-7546 SMC0111-7249 SMC0112-7236 SMC0116-7259 NGC288 NGC104 NGC7078 NGC2141 NGC2682 NGC5927 NGC6352 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [NA] [FORS only] Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [Y] [FORS only] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [Y] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.