README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 074.A-0745A Principal Investigator Name: J.D. Kurk Principal Investigator E-mail Address: kurk@arcetri.astro.it Principal Investigator Telephone Number: ++39-055-2752262 Principal Investigator Postal Address: Osservatorio Astrofisico di Arcetri Largo E. Fermi 5, 50125, Firenze, Italy Instrument: ISAAC OPC Priority Class: B OPC Approved Total Execution Time: 5hr Estimated Total Execution Time (including overheads): 4:53hr README File Submission Date: 300704 Programme Description ===================== General Overview ---------------- We aim to detect the faint HeII1640 emission line of a galaxy at z=6.5. The line will be at 1.2330 micron, which is in the J band. ISAAC spectroscopy will be carried out in MR mode with a slit of 1.0" width and four exposures of 900s in one OB of 1h13m. Acquisition will be done on an 18th magnitude star, then an offset of 25" will be carried out. This will bring the galaxy in the slit, as well as the same 18th magnitude acquisition star. An ABBA pattern will be used with offsets of 12" and an additional offset of 2" between the As and Bs. Between the OBs there is an additional offset of 0.5" in order to never sample the same part of the CCD. We have taken the slit length of <90" into account. Approved Waiver Request Summary ------------------------------- Waiver 074.A-0745A.01 was submitted on 280704 and accepted on 300704. We have asked to extend the maximum time of an OB to 1h15m to obtain the highest s/n possible given the low sky background between the skylines in the J-band and the necessity to carry out at least four observations per OB to do proper background subtraction. Critical Observing Condition Constraints ---------------------------------------- Only those specified in the constraint set of the OBs: seeing < 1.0", airmass < 1.5, FLI < 0.7, MAD > 60d. Note that we have followed the advise in the ISAAC manual for J-band MR spectroscopy. Time Critical Aspects --------------------- None. Special Calibration Information ------------------------------- No special calibrations to be taken, but, please, do not skip the acquisition images as they will be useful for our science. ToO Information --------------- None. Pre-Imaging Requirements ------------------------ This is not a pre-imaging program. Source of preimaging: Object coordinates and finding charts are based on a deep image through ESO's z_SPECIAL+43 filter. OB Information ============== List of Science OBs ------------------- KCS1166 HeII 1-4 KCS1166 HeII 2-4 KCS1166 HeII 3-4 KCS1166 HeII 4-4 Apart from small (<2") differences in offsets, all four OBs are identical. Brightest star in the field is 15th magnitude (in R band). Just outside the ISAAC field, there is a 14th magnitude star (in R band). Total Number of Submitted Science OBs: 4 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? Y Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? Y If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? NA Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? NA [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? Y [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? NA [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [Y/N/NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [Y/N/NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [Y/N/NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [Y/N/NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [Y/N/NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.