README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 074.A-0697(A) Principal Investigator Name: M. Dessauges-Zavadsky Principal Investigator E-mail Address: mirolava.dessauges@obs.unige.ch Principal Investigator Telephone Number: +41-22-755.26.11 Principal Investigator Postal Address: Geneva Observatory / 51, Ch. des Maillettes / CH-1290 Sauverny / Switzerland Instrument: VIMOS OPC Priority Class: B OPC Approved Total Execution Time: 8.0 Estimated Total Execution Time (including overheads): 7.9 README File Submission Date: August 19, 2004 Programme Description ===================== General Overview ---------------- This is a simple integral field spectroscopy programme directed on VIMOS with the IFU mode, which consists of obtaining seven fields (of 47 minutes exposure time) of the quasar Q0347-3819 with the HR_blue grism and an IFU magnification of 0.67 arcsec per fibre. The goal is to reach an enough high signal-to-noise ratio to be able to detect the Lyman-alpha emission of the intervening damped Lyman-alpha system at z_abs = 3.025 in the field of the quasar. The predicted flux of the Lyman-alpha emission line expected at 4893 A of the associated galaxy is of the order of 10^{-17} erg/s/cm^2. Approved Waiver Request Summary ------------------------------- We have requested that we have longer OBs than the allowed execution time of 1h05min. This request was submitted on August 10, 2004 and was approved on August 18, 2004. Critical Observing Condition Constraints ---------------------------------------- We have no critical observing condition constraints. Time Critical Aspects --------------------- We have no time critical aspects. Please, note that our target Q0347-3819 is well visible from the beginning of October to the end of December. Special Calibration Information ------------------------------- In the IFU mode on VIMOS, instrumental flexures will introduce flat field residuals and wavelength calibration offsets if calibration data are taken at a very different rotator angle than the science exposure. Therefore, nightime calibrations are mandatory for IFU. We have attached to each science OB a NightCalib calibration template which provides 3 flat-fields and 1 arc taken at the same rotator position of the science target. ToO Information --------------- This is not a To0 programmme. Pre-Imaging Requirements ------------------------ No pre-imaging is required for this programme. Source of preimaging: Not applicable OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Total Number of Submitted Science OBs: 7 Q0347-3819_HRblue_1 Q0347-3819_HRblue_2 Q0347-3819_HRblue_3 Q0347-3819_HRblue_4 Q0347-3819_HRblue_5 Q0347-3819_HRblue_6 Q0347-3819_HRblue_7 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.