README Template 74.1 ESO Programme ID: 074.A-0668(B) Principal Investigator Name: D. Vergani Principal Investigator E-mail Address: daniela.vergani@obspm.fr Principal Investigator Telephone Number:+33 (0)1 45 07 7407 Principal Investigator Postal Address: Observatoire de Paris Meudon, GEPI (18) 5, Place Jules Janssen, F-92195 Meudon Cedex Instrument: VIMOS OPC Priority Class: B OPC Approved Total Execution Time: 12 hours Estimated Total Execution Time (including overheads): 12 hours README File Submission Date: 23.08.2004 Programme Description ===================== General Overview ---------------- High redshift radio galaxies are commonly surrounded by extended (up to 100 kpc) halos. Halos present two distinct kinematic components: A high surface brightness structure with extreme kinematics likely due to jet/gas interactions and a quiescent kinematic component at low surface brightness. This latter is, however, the sole component intimately related to the galaxy formation. Only by using the integral field technique we can isolate the unperturbed component and assess the gas configuration, the signature of gas rotation and the enrichment by heavy elements of the gaseous reservoirs from which galaxies have formed. The study of the kinematics and properties of these structures will allow us to compare intermediate with hogh redshift halos and shed light on the galaxy formation. Approved Waiver Request Summary ------------------------------- The waiver request concerns the technical requirement to execute OBs longer than one hour for the VIMOS/VLT IFU mode for both target galaxies: Run A (4C 03.24 RA:12 45 38.36 DEC:+03 23 20.7 at z=3.56) and Run B (3C 267 RA:11 49 56.52 DEC:+12 47 18.9 at z=1.14). Mapping low signal components are extremely challenging and exact computation on the spatially resolved flux have never been made before at such high redshift. The requested exposure time has been computed on the basis of a flux averaged over the source extension, which means that S/N in the outer, most interesting regions of the candidates will be lower of a factor depending on the gas profile, which is what we want to map. Such a computation is very difficult, if not impossible, to do with ETC and extremely model dependent. The two waiver requests for VLT-VIMOS runs 74.A-0668(A) and (B) have been approved by Paranal Science Operations, with the restriction that if the conditions degrade in violation of the constraints after the first hour, the OB will not be repeated. Critical Observing Condition Constraints ---------------------------------------- None Time Critical Aspects --------------------- None Special Calibration Information ------------------------------- None ToO Information --------------- Not Applicable Pre-Imaging Requirements ------------------------ Not Applicable Source of preimaging: OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) Total Number of Submitted Science OBs: 6 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: None, standard calibrations are sufficient for this programme. OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y/N/NA] Y Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y/N/NA] Y If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y/N/NA] NA Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y/N/NA] NA [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] NA [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [Y/N/NA] NA [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA] NA [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] NA [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [Y/N/NA] NA [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [Y/N/NA] NA [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [Y/N/NA] NA [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [Y/N/NA] NA [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [Y/N/NA] NA If you answered "NO" to any of these questions, please revise your OBs *before* submission.