README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 074.A-0631(C) Principal Investigator Name: Sophie Maurogordato Principal Investigator E-mail Address: maurogor@obs-nice.fr Principal Investigator Telephone Number: +33-4-92-00-31-50 Principal Investigator Postal Address: Laboratoire CASSIOPEE, CNRS, Observatoire de la Cote d'Azur, BP4229, 06304 Nice, Cedex 4, France Instrument: WFI OPC Priority Class: B OPC Approved Total Execution Time: 2.8 Estimated Total Execution Time (including overheads): 2.8 README File Submission Date: 25 August 2004 Programme Description ===================== General Overview ---------------- This program aims to perform the imaging of the galaxy cluster Abell 2440, through the medium-band filter MB#721/25_ESO847. The observations are divided in two observing blocks for the cluster, and two observing blocks for the calibration standards Landolt SA113 and SA114 to be observed with the same filter, one immediatly before, and the other immediatly after the science observations of the cluster. Approved Waiver Request Summary ------------------------------- Critical Observing Condition Constraints ---------------------------------------- Time Critical Aspects --------------------- Special Calibration Information ------------------------------- Photometric calibration: It is imperative to observe the photometric standards through the same filter MB#721/25_ESO847 the same night as the science observations. ToO Information --------------- Pre-Imaging Requirements ------------------------ Source of preimaging: OB Information ============== List of Science OBs ------------------- A2440_F721_1 A2440_F721_2 + associated stars for photometric calibration: Land_SA113 Land_SA114 Total Number of Submitted Science OBs: 4 Note that the standards stars for photometric calibrations Land_SA113 and Land_SA114 are the same in proposals 074.A-0631A and 074.A-0631C and can be performed only once, if observations of science targets of proposals 074.A-0631A and 074.A-0631C are done within the same night. List of Calibration OBs with Associated Science OBs --------------------------------------------------- CALIB-A2440 Total Number of Submitted Calibration OBs: 1 Note that the night calibration OBs are the same in proposals 074.A-0631A, 074.A-0631B, 074.A-0631C and can be performed only once OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y/N/NA] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y/N/NA] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y/N/NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y/N/NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [Y/N/NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [Y/N/NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [Y/N/NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [Y/N/NA] [MIDI only] Did you indicate for each science star OB the corresponding calibrator star OB name in the ReadMe file as well as in the comments of the OB ? [Y/N/NA] [MIDI only] If you use calibrator stars which are not in the CalVin database, did you specify their characteristics in the ReadMe file and in the OBs ? [Y/N/NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.