README Template 74.1 (please do not delete the README Template Version line!) ESO Programme ID: 074.A-0524(A) Principal Investigator Name: Tomoki Saito Principal Investigator E-mail Address: tsaito@astron.s.u-tokyo.ac.jp Principal Investigator Telephone Number: +81-3-5841-4267 Principal Investigator Postal Address: 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033 Instrument: VIMOS OPC Priority Class: A OPC Approved Total Execution Time: 1 hour Estimated Total Execution Time (including overheads): 00:50:15.000 README File Submission Date: 28 Sep. 2004 Programme Description ===================== General Overview ---------------- Pre-imaging for VIMOS multi-object spectroscopy with 2 MOS fields + 1 auxiliary MOS field. "PRE SXDF1" was revised and resubmitted at 28 Sep. 2004. Approved Waiver Request Summary ------------------------------- Critical Observing Condition Constraints ---------------------------------------- airmass < 1.2 Time Critical Aspects --------------------- none Special Calibration Information ------------------------------- none ToO Information --------------- none Pre-Imaging Requirements ------------------------ Only 10 minutes exposure for each MOS field is required with nomal imaging procedure. Source of preimaging: 3 MOS fields within the Subaru/XMM-Newton Deep Field OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) PRE SXDF 1, 2, & 3. "PRE SXDF 3" is for auxiliary mask for the following cases: 1. The S/N is unexpectedly high. 2. Diffuse sources (main targets) cannot be taken due to the weather condition. Total Number of Submitted Science OBs: 3 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: OB Compliance Checks ==================== Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [N] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [N] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [Y] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [Y]