README Template 74.1 ESO Programme ID: 074.A-0447(C) Principal Investigator Name: Fabian Walter Principal Investigator E-mail Address: walter@mpia.de Principal Investigator Telephone Number: +49-6221-528-225 Principal Investigator Postal Address: Max-Planck-Institute for Astronomy / Koenigstuhl 17 / D-69117 Heidelberg / Germany Instrument: ISAAC OPC Priority Class: B OPC Approved Total Execution Time: 09:30:00 Estimated Total Execution Time (including overheads): 09:27:50 README File Submission Date: 25 August 2004 Programme Description ===================== General Overview ---------------- This program is part of a survey of 5 high-redshift quasars (z~6). Due to the faintness of the targets, reference stars are targeted first, and the quasars are found through offsets from the reference star in the acquisition run. Afterwards, the slit is centered on the target quasar. The position angle is chosen in such a way that the reference star remains in the slit. 074.A-0447(C) is a spectroscopic programme consisting of ten observing blocks. Seven blocks are taken with the Ks filter, three blocks are taken with the SZ filter. The same object and reference star are observed with the same slit width/orientation in all observing blocks. Approved Waiver Request Summary ------------------------------- No waiver requests. Critical Observing Condition Constraints ---------------------------------------- No additional critical constraints for this programme. Time Critical Aspects --------------------- There are no time critical aspects for this programme. Special Calibration Information ------------------------------- Only standard calibration is required. ToO Information --------------- This is not a ToO programme. Pre-Imaging Requirements ------------------------ No pre-imaging is required for this programme. Source of preimaging: Not applicable OB Information ============== List of Science OBs ------------------- (for ISAAC imaging, please indicate the magnitude of the brightest star in the field for each OB) This is a spectroscopic programme Total Number of Submitted Science OBs: 10 J1044-0125_K_1 J1044-0125_K_2 J1044-0125_K_3 J1044-0125_K_4 J1044-0125_K_5 J1044-0125_K_6 J1044-0125_K_7 J1044-0125_SZ_1 J1044-0125_SZ_2 J1044-0125_SZ_3 List of Calibration OBs with Associated Science OBs --------------------------------------------------- No extra calibration OBs are required. Total Number of Submitted Calibration OBs: Not applicable OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] Do all your Finding Charts comply with the both the general and instrument-specific finding chart requirements? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [NA] [FORS only] Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [NA] [FORS only] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [NA] [ISAAC only] Did you indicate the magnitude of the brightest star in the field for ISAAC imaging observations? [NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [FLAMES only] Did you specify the S/N ratio (at some reference wavelength and per single exposure) you expect to reach with these observations? [NA] [VIMOS only] Did you specify suitable guide stars for all your OBs using Guidecam? [NA] [VIMOS only] Did you check that the chosen guide stars are suitable for all the offset positions and that they do not produce unacceptable vignetting of the field of view? [NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.